Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Mitsubishi Electric · Homeowner Summary + Technical Datasheet

Mitsubishi Electric Starmex R32 Hybrid 7.1 kW Middle-Static Ducted + Wall System 4 (MXY-5H48VG / 1× PEY-M71JAL Concealed Ducted + 3× MSXY-FP10VG Wall)

In Plain English: Suited for Whole Flat / 2–4 Rooms, running at 19 dBA (Whisper-quiet bedroom) on low fan speed. Expect an estimated electricity bill of ~S$1,117/year (~S$93/month) at 8 hrs/day. Highest-capacity Starmex R32 hybrid System 4 pairing the 9.20 kW (1.40–13.00 kW, 1.89 kW rated input, 8.43 A running current) MXY-5H48VG outdoor condenser with 1× PEY-M71JAL 7.1 kW (24,225 BTU/h, 1.7–8.5 kW range) middle-static ceiling-concealed ducted unit (1,100×732×250 mm, 30.5 kg, 17.5–21.0–25.0 m³/min airflow, 35–50–70–100–125 Pa ESP, 0.17 kW / 1.97 A max indoor current) plus 3× MSXY-FP10VG bedroom wall units (3× 0.27 A = 0.81 A). Combined indoor current is 2.78 A, remaining within the 3.0 A MXY-H indoor current limit.
Cooling Capacity
31,390 BTU/h
9.2 kW nominal
Efficiency
4.87 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$6,950
Power: ~S$1,117/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUMXY-5H48VG / 1× PEY-M71JAL (7.1 kW Middle-Static Ducted) + 3× MSXY-FP10VG (2.8 kW Wall)
System Architecture & CompressorMulti-Split System 4 (Hybrid High-Capacity Middle-Static Concealed Ducted + Wall-Mounted) · Twin Rotary DC Inverter Compressor with PAM Control
Rated Capacity & Inverter Modulation31,390 BTU/h (9.2 kW) · Modulation: 4,777 – 44,356 BTU/h (1.40 – 13.00 kW)
Efficiency Index & Tick StandingNEA 5-Tick Multi-Split (COP 4.87 W/W Rated) · 5
Indoor & Outdoor Sound PressureIndoor: PEY-M71JAL: 30–34–39 dBA · MSXY-FP10VG: 19–45 dBA · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · PEY-M71JAL: Ø9.52 mm Liquid / Ø15.88 mm Gas · 3× MSXY-FP10VG: Ø6.35 mm Liquid / Ø9.52 mm Gas · 80
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Starmex R32 Inverter Multi-Split Catalogue (Pages 3, 20 & 22: MXY-5H48VG, PEY-M71JAL & MSXY-FP10VG) ↗
How a System 4 Aircon Connects (4 Indoor Units to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 4 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)CONNECTED #2Room 2 · Common Bedroom 2 (9K BTU)CONNECTED #3Room 3 · Study / Bedroom 3 (9K BTU)CONNECTED #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$4,496S$8,1864-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$5,597S$8,787Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$7,772S$10,522
Engineering Reference

Technical Schematic

Mitsubishi Electric Starmex MXY-5H48VG + PEY-M71JAL (7.1 kW) Hybrid System 4 Piping & 2.78 A Current Budget Schematic
Mitsubishi Electric Starmex MXY-5H48VG + PEY-M71JAL (7.1 kW) Hybrid System 4 Piping & 2.78 A Current Budget Schematic① PEY-M60JAL (6.0 kW, 900 mm width, 1.39 A) vs ② PEY-M71JAL (7.1 kW, 1,100 mm width, 1.97 A, Ø9.52/Ø15.88 mm piping); ③ Combined indoor current budget (1.97 A + 3×0.27 A = 2.78 A ≤ 3.00 A MXY-H limit).