Daikin Troubleshooting
Daikin Blinking Light & Error Codes
Complete Daikin Fault Code Encyclopedia Table
| Code | Part Affected | Urgency | Plain-English Meaning & What to Try First | Manual |
|---|---|---|---|---|
| U4 | System / Inter-Unit Comms | High — Cooling Halted | Failure of signal transmission between indoor fan coil unit and outdoor inverter condensing unit. Safe check: Verify outdoor isolator switch and MCB breaker are ON; power off at main breaker for 5 minutes to clear transient voltage latch. If U4 returns immediately, interconnecting control cable or outdoor inverter PCB requires licensed technician multimeter testing. | Source ↗ |
| U0 | Refrigerant Circuit | High — Compressor Protection | Refrigerant shortage warning — low suction pressure or excessive discharge/heat-exchanger superheat detected. Safe check: Switch unit OFF so compressor does not run dry. Inspect outdoor flare valves for oily residue and book pressure/leak testing before any R32 gas recharge. | Source ↗ |
| A5 | Indoor Heat Exchanger | Moderate — Airflow / Coil | Indoor heat-exchanger freeze-up protection in cooling mode or high-pressure control in heating mode. Safe check: Open front grille, wash clogged PM2.5 / mesh pre-filters, and ensure louvers are unobstructed. Persistent A5 after filter cleaning points to restricted evaporator coil or thermistor drift. | Source ↗ |
| A6 | Indoor Fan Assembly | Moderate — Fan Motor | Indoor fan motor lock, overload, or Hall-sensor feedback abnormality. Safe check: Power off breaker first; check whether foreign debris blocks the cross-flow blower wheel. Requires fan motor or indoor PCB inspection if wheel spins freely. | Source ↗ |
| E7 | Outdoor Condenser Fan | High — Outdoor Heat Rejection | Outdoor DC fan motor lock or overcurrent malfunction on condensing unit. Safe check: Visually check outdoor condenser grille (from indoors/balcony safely) for leaves or plastic bags blocking fan blades; arrange technician DC fan motor/driver check. | Source ↗ |
| L5 | Outdoor Inverter IPM | Critical — Inverter Drive | Inverter instantaneous output overcurrent fault (IPM module or compressor winding fault). Safe check: Do not repeatedly reset breaker. Shut down isolator and schedule inverter board / compressor insulation resistance (Megger) test. | Source ↗ |
| U2 | Power Supply / DC Bus Voltage | High — Voltage Drop / Overvoltage | Malfunction of power supply or instantaneous power failure (insufficient supply voltage or DC bus overvoltage/undervoltage protection). Safe check: Verify that the main DB breaker and outdoor isolator provide stable 220–240 V power; switch off the breaker for 5 minutes to reset transient grid sags. Persistent U2 requires outdoor inverter PCB capacitor and rectifier testing. | Source ↗ |
| E5 | Outdoor Inverter Compressor | Critical — Overload / Lock | Inverter compressor motor overload, overheat, or rotor lock detected during startup or high-load operation. Safe check: Switch unit OFF immediately; confirm outdoor service valves are open and condenser coil is not blocked. Requires technician manifold pressure and compressor winding resistance check. | Source ↗ |
| F3 | Discharge Pipe Temperature | High — High Discharge Temp | High-temperature abnormality of the outdoor compressor discharge pipe (refrigerant shortage, clogged capillary/EEV, or faulty discharge thermistor). Safe check: Turn unit off so compressor oil does not overheat; book a refrigerant pressure/leak test and discharge pipe thermistor inspection. | Source ↗ |
| C9 | Indoor Return Air Sensor | Moderate — Room Thermistor | Malfunction of indoor suction (return air) temperature thermistor (open or short circuit). Safe check: Power-cycle the main breaker once; if C9 remains on remote check, reseat or replace the clip-on return air thermistor on the indoor control PCB. | Source ↗ |
| E6 | Outdoor Compressor Motor | High — Compressor Lock / Overcurrent | Standard compressor motor lock or overcurrent detected due to closed stop valves, locked rotor, or winding insulation failure. Safe check: Switch off the outdoor isolator breaker for 5 minutes and verify stop valves are open; if E6 recurs on restart, book a technician to test compressor winding resistance and start current. | Source ↗ |
| F6 | Outdoor Condenser Thermal Control | Moderate — High Pressure / Condenser Overheat in Cooling | High pressure control or outdoor heat-exchanger overheat during cooling caused by fouled condenser fins, obstructed outdoor airflow, or refrigerant overcharge. Safe check: Ensure the outdoor condenser ledge has unobstructed airflow clearance and schedule an outdoor condenser coil wash and refrigerant pressure check. | Source ↗ |
| J3 | Outdoor Discharge Pipe Thermistor | Moderate — Discharge Sensor Fault | Malfunction (open or short circuit) of the outdoor compressor discharge pipe thermistor (R3T) or loose PCB harness connection. Safe check: Power-cycle the main AC breaker for 5 minutes; persistent J3 requires testing discharge pipe thermistor resistance and replacing the sensor harness. | Source ↗ |
| A3 | Indoor Condensate Drain System | Moderate — Drain Water Level Abnormality | Indoor condensate drain water level control system abnormality triggered by a tripped float switch, clogged drain pipe, or faulty drain pump. Safe check: Turn off the indoor unit to prevent water overflow and clear the PVC condensate drain line, float switch, and drain pump reservoir. | Source ↗ |
| H8 | Outdoor Compressor CT Sensor | High — Compressor Input Current Sensor Fault | Outdoor compressor input current transformer (CT) or DC current sensor circuit abnormality on the inverter power board. Safe check: Switch off the main isolator for 5 minutes; if H8 persists, have a technician inspect the outdoor reactor harness, CT sensor, and inverter PCB. | Source ↗ |
| A1 | Indoor Unit Main Printed Circuit Board (PCB) | High — Indoor Microcomputer / EEPROM Fault | Malfunction of indoor unit PCB due to defective zero-cross detection, corrupted EEPROM memory, or external electrical noise. Safe check: Reset the 20A circuit breaker for 5 minutes to clear transient line noise; if A1 recurs immediately, inspect and replace the indoor unit main PCB. | Source ↗ |
| A7 | Indoor Swing Flap Stepper Motor / Limit Cam | Low — Horizontal Louver / Swing Mechanism Fault | Malfunction of swing flap motor caused by a defective swing stepper motor, broken connection cable, jammed flap-cam micro-switch, or indoor PCB driver fault. Safe check: Power off the unit and check that the horizontal airflow louver is not physically jammed or taped; have a technician inspect the swing motor harness and stepper coil. | Source ↗ |
| A9 | Indoor Electronic Expansion Valve (EEV) Drive | High — Indoor Refrigerant Metering Fault | Malfunction of indoor electronic expansion valve caused by a defective EEV stepper coil, disconnected relay harness, or indoor unit PCB drive circuit fault. Safe check: Isolate power and verify the 5-pin/6-pin EEV coil connector on the indoor PCB and measure coil winding resistance across each phase. | Source ↗ |
| C4 | Indoor Heat Exchanger Liquid Pipe Thermistor | Medium — Evaporator Liquid Line Sensor Fault | Malfunction of liquid pipe thermistor for indoor heat exchanger due to an open/shorted sensor, loose PCB connector contact, or defective indoor unit PCB. Safe check: Inspect the indoor heat exchanger liquid pipe thermistor plug on the indoor PCB and measure thermistor kΩ resistance against the Daikin temperature chart. | Source ↗ |
| C5 | Indoor Heat Exchanger Gas Pipe Thermistor | Medium — Evaporator Gas Line Sensor Fault | Malfunction of gas pipe thermistor for indoor heat exchanger due to an open/shorted thermistor lead, poor connector contact, or defective indoor unit PCB. Safe check: Check the indoor gas pipe thermistor connector for moisture ingress and verify resistance continuity across the thermistor leads. | Source ↗ |
| C7 | Indoor Front Panel Driving Motor / Limit Switch | Low — Motorized Front Panel Actuation Fault | Front panel driving motor fault caused by a defective front panel driving motor or defective limit switch. Safe check: Power down the indoor unit, inspect the front panel track for physical obstruction, and test the panel limit switch and driving motor harness. | Source ↗ |
| CA | Indoor Discharge Air Temperature Thermistor | Medium — Discharge Air Sensor Open/Short Fault | Malfunction of discharge air thermistor due to a defective discharge air thermistor, defective indoor unit PCB, or loose connector contact. Safe check: Inspect the discharge air thermistor connector on the indoor PCB and verify thermistor resistance against the Daikin temperature-resistance curve. | Source ↗ |
| CC | Indoor Humidity Sensor System | Low — Humidity Sensor Circuit Abnormality | Malfunction of humidity sensor system due to a defective indoor humidity sensor or corroded/loose PCB connector contact. Safe check: Clean moisture/dust around the indoor humidity sensor housing and check the sensor plug seating on the indoor unit PCB. | Source ↗ |
| CJ | Remote Controller Room Temperature Thermistor | Low — Remote Thermostat Sensor Fault | Room temperature thermistor in remote controller abnormality caused by a defective thermistor in the remote controller, defective remote controller PCB, or external electrical noise. Safe check: Reset power and check wired/wireless remote controller PCB connections; switch temperature sensing to the indoor return-air thermistor (C9) if supported. | Source ↗ |
| E1 | Outdoor Unit Control Printed Circuit Board (PCB) | High — Outdoor Control PCB / Relay Wiring Fault | Defective outdoor unit PCB or defective connection of inside/outside relay wires. Safe check: Isolate mains power at the 20A double-pole isolator for 5 minutes, inspect indoor-to-outdoor relay harness terminals, and replace the outdoor control PCB if E1 persists. | Source ↗ |
| E3 | Outdoor Condenser High Pressure Switch (HPS) Circuit | Critical — High Pressure Switch Actuation | Actuation of the outdoor unit high pressure switch (HPS) due to a dirty outdoor heat exchanger, clogged refrigerant piping, defective high pressure switch, or loose HPS connector contact. Safe check: Switch off the circuit breaker for 5 minutes and check that the outdoor condenser coil and aircon ledge louvers have unobstructed airflow; if E3 trips again, leave the system off and book a licensed technician to inspect condenser heat rejection, stop valves, and HPS continuity. | Source ↗ |
| H6 | Inverter Compressor Rotor Position Detection Sensor | Critical — Compressor Position Sensor Fault | Malfunction of the inverter compressor position detection sensor caused by faulty contact on the compressor lead cable, a defective compressor motor, or a defective outdoor unit inverter PCB. Safe check: Turn off the main isolator or circuit breaker for 5 minutes to clear transient inverter lockups; if H6 reappears on startup, stop operating the unit and schedule a technician to inspect the UVW compressor harness and outdoor PCB. | Source ↗ |
| L4 | Outdoor Inverter Heatsink Radiation Fin & Thermistor | High — Inverter Radiation Fin Overheat Protection | Outdoor inverter power module radiation fin temperature rise above safety threshold due to blocked heatsink cooling airflow, short-circuited exhaust air, or a defective radiation fin thermistor. Safe check: Power down the system at the breaker for 10 minutes to let the outdoor inverter heatsink cool and verify nothing is blocking the outdoor fan discharge; if L4 persists, book a technician to clean the heatsink fins and test the fin temperature thermistor. | Source ↗ |
| E4 | Outdoor Suction Low Pressure Switch (LPS) & Sensor Circuit | Critical — Low Pressure Switch Actuation | Actuation of the outdoor unit low pressure switch (LPS) due to an abnormal drop in suction pressure, refrigerant shortage/restriction, closed liquid/gas stop valve, defective low pressure sensor, or defective outdoor unit PCB. Safe check: Switch off the circuit breaker for 5 minutes and inspect indoor air filters for heavy dust blockage; if E4 recurs after restart, leave the system off and book a licensed technician to verify stop valve positions, refrigerant suction pressure, and LPS continuity. | Source ↗ |
| H9 | Outdoor Ambient Air Temperature Thermistor | Medium — Outdoor Air Thermistor Fault | Malfunction of the outdoor unit ambient air thermistor caused by a defective thermistor sensor element, loose harness connector contact, or defective outdoor unit control PCB. Safe check: Reset power at the main circuit breaker for 5 minutes; if H9 persists, schedule a technician to measure the outdoor ambient thermistor resistance curve and inspect the outdoor PCB sensor header. | Source ↗ |
| J6 | Outdoor Condenser Heat Exchanger Thermistor | High — Outdoor Heat Exchanger Thermistor Fault | Malfunction of the outdoor condenser heat exchanger thermistor due to a defective coil thermistor bead, loose connector contact, or defective outdoor unit PCB. Safe check: Switch off the circuit breaker for 5 minutes to clear temporary sensor glitches; if J6 reappears, book a technician to test the outdoor heat exchanger coil thermistor resistance and PCB input circuit. | Source ↗ |
| E9 | Outdoor Electronic Expansion Valve (EEV) Coil & Harness | High — Outdoor EEV Stepper Coil Fault | Malfunction of the outdoor unit electronic expansion valve (EEV) coil caused by a disconnected EEV wiring connector, open/shorted EEV stepper coil winding, or defective outdoor unit control PCB. Safe check: Switch off the circuit breaker for 5 minutes and restore power so the EEV performs its home-pulse initialization sequence; if E9 recurs, book a licensed technician to measure the 20V stepper coil winding resistance and inspect the outdoor PCB EEV header. | Source ↗ |
| L8 | Outdoor Inverter Compressor Overcurrent & Lead Harness | Critical — Inverter Compressor Overcurrent Cutout | Malfunction of overcurrent in the inverter compressor caused by mechanical compressor overload, disconnected or broken compressor coil lead wiring, or a defective outdoor inverter PCB. Safe check: Turn off the main isolator or circuit breaker for 5 minutes and verify outdoor condenser airflow is unobstructed; if L8 trips again, keep the system off and schedule a technician to test compressor winding insulation/resistance and the inverter PCB. | Source ↗ |
| U5 | Indoor Unit to Remote Controller Communication Bus | Medium — Remote Controller Transmission Error | Malfunction of signal transmission between the indoor unit and remote controller due to external electrical noise, improper main/sub address setting when two wired remote controllers are connected, or a defective remote controller/indoor unit PCB. Safe check: Cycle the air-conditioner circuit breaker off for 5 minutes to reset the remote controller bus; if using dual wired BRC controllers, have a technician verify main/sub jumper settings and shield the P1/P2 control wire from high-voltage power cables. | Source ↗ |
| L9 | Outdoor Inverter Compressor Startup & Stall Prevention | Critical — Compressor Startup / Stall Prevention Error | Malfunction of inverter compressor startup (stall prevention) caused by a closed liquid/gas stop valve, excessive differential pressure prior to compressor start, miswired compressor phases, defective compressor, or defective inverter PCB. Safe check: Switch off the circuit breaker for 5 minutes to allow high/low refrigerant pressures to equalize before restarting; if L9 trips immediately on startup, leave the system off and book a technician to verify stop valves are open and test the compressor and inverter board. | Source ↗ |
| LC | Outdoor Control PCB to Inverter PCB Internal Bus | High — Control-to-Inverter PCB Transmission Error | Malfunction of internal serial transmission between the outdoor control PCB and the outdoor inverter power PCB due to a loose interconnect harness, external electromagnetic noise, defective inverter compressor, or defective outdoor control/inverter PCB. Safe check: Cycle the main circuit breaker off for 5 minutes to reset both outdoor microcontrollers; if LC persists, schedule a technician to inspect the internal PCB-to-PCB ribbon harness and test the outdoor control and inverter boards. | Source ↗ |
| UA | System Indoor-Outdoor Combination & Field Capacity Setting | High — Improper Indoor/Outdoor Unit Combination | Improper combination of indoor and outdoor units caused by mismatched refrigerant type or model series, excessive connected indoor units, missing PCB field setting after spare outdoor PCB replacement, or wrong indoor/outdoor power supply wiring. Safe check: Switch off the breaker for 5 minutes; if UA appears after a PCB replacement or new installation, have the installer verify indoor/outdoor SKU compatibility and configure the outdoor PCB field/capacity setting adaptor. | Source ↗ |
| H0 | Outdoor Compressor Sensor System & Harness | High — Compressor Sensor System Fault | Malfunction of the inverter compressor sensor system caused by a disconnected or damaged compressor sensor wiring harness, poor connector contact, or a defective outdoor unit control/inverter PCB. Safe check: Switch off the circuit breaker for 5 minutes to clear temporary sensor latches; if H0 reappears, keep the unit off and schedule a technician to inspect the outdoor compressor sensor harness and outdoor PCB. | Source ↗ |
| H7 | Outdoor Condenser Fan Motor Hall IC Position Signal | High — Outdoor Fan Motor Signal Fault | Abnormal position feedback signal from the outdoor unit DC fan motor caused by a broken or shorted fan motor lead wire, disconnected Hall sensor connector, fan motor circuit failure, or defective outdoor inverter PCB. Safe check: Turn off the circuit breaker for 5 minutes and verify that the outdoor condenser fan blade spins freely without obstruction; if H7 recurs, book a technician to test the outdoor DC fan motor Hall sensor harness and inverter PCB. | Source ↗ |
| U1 | 3-Phase Power Supply Phase Sequence & Open-Phase Monitor | Critical — Reverse Phase / Open Phase Fault | Reverse phase sequence (L1/L2/L3 transposed) or open phase (loss of T-phase) on a 3-phase 380–415V outdoor condenser power supply, or a defective outdoor unit main PCB (A1P). Safe check: Switch off the 3-phase isolator immediately; never force-run a scroll/swing compressor under reverse phase. Have an EMA-licensed electrician or HVAC technician verify L1-L2-L3 phase rotation and check all three supply phases for blown fuses or loose terminals. | Source ↗ |
| J5 | Outdoor Suction Pipe Temperature Thermistor | Medium — Outdoor Suction Pipe Thermistor Fault | Malfunction of the outdoor unit suction pipe thermistor caused by a defective thermistor sensor element, loose PCB connector contact, or defective outdoor unit control PCB. Safe check: Switch off the circuit breaker for 5 minutes to clear temporary sensor glitches; if J5 recurs, book a licensed technician to measure the outdoor suction pipe thermistor resistance curve and inspect the outdoor PCB sensor header. | Source ↗ |
| L3 | Outdoor Electrical Switch Box & Heatsink Enclosure | High — Electrical Component Box Temperature Rise | Abnormal temperature rise inside the outdoor unit electrical component box due to short-circuited hot condenser exhaust air, a failed outdoor fan motor, defective power transistor, or defective outdoor unit PCB. Safe check: Turn off the circuit breaker for 10 minutes to let the outdoor electrical box cool and ensure aircon ledge louvers are open with unobstructed fan discharge; if L3 reappears, schedule a technician to inspect the outdoor fan motor and inverter switch box. | Source ↗ |
| P4 | Outdoor Inverter Radiation Fin Temperature Sensor | High — Radiation Fin Thermistor Sensor Fault | Malfunction of the outdoor inverter radiation fin temperature sensor caused by a defective fin thermistor probe, defective inverter PCB, defective inverter compressor, or outdoor fan motor fault. Safe check: Cycle the main circuit breaker off for 5 minutes; if P4 persists on restart, book a technician to test the inverter heatsink radiation fin thermistor resistance and inspect the outdoor inverter PCB. | Source ↗ |
| J7 | Outdoor Refrigerant Circuit Liquid Pipe Thermistor | Warning / Sensor Fault | Malfunction of refrigerant circuit liquid pipe thermistor caused by a defective liquid pipe thermistor probe, loose thermistor harness connector contact, or a defective outdoor unit control PCB. Safe check: Switch off the outdoor isolator before opening the condenser service cover. Verify that the liquid pipe thermistor clip is seated tightly on the subcooling liquid line and that the thermistor plug is firmly locked into the outdoor control PCB. | Source ↗ |
| J9 | Outdoor Refrigerant Circuit Gas Pipe / Subcooling Receiver Thermistor | Warning / Sensor Fault | Malfunction of refrigerant circuit gas pipe thermistor caused by a defective gas pipe thermistor element, loose or oxidized connector contact, or a defective outdoor unit control PCB. Safe check: Power down the outdoor isolator and inspect the outdoor gas pipe thermistor lead for insulation chafing against copper return bends. Confirm the sensor resistance matches Daikin's temperature-resistance curve before replacing the outdoor PCB. | Source ↗ |
| P1 | Outdoor Inverter Main Circuit Power Supply & DC Bus Capacitor | Critical / Inverter Protection | Power supply voltage imbalance or inverter PCB malfunction triggered by an open phase on three-phase supply, excessive interphase voltage imbalance, a defective main-circuit smoothing capacitor, faulty main-circuit wiring, or a defective inverter PCB. Safe check: Have a licensed electrical worker measure line-to-line voltage across L1, L2, and L3 at the outdoor terminal block under load to verify phase balance within 2%. Do not touch the main-circuit DC link capacitors until the high-voltage discharge LED has fully extinguished. | Source ↗ |
| H3 | Outdoor High Pressure Switch (HPS) Safety Loop | Critical / Pressure Safety Circuit | Malfunction of high pressure switch (HPS) safety sensing circuit caused by a defective high pressure switch contact, broken HPS harness wire, loose connector contact, or a defective outdoor unit control PCB. Safe check: Switch off the outdoor isolator and verify with a continuity meter whether the normally-closed HPS contact (S1PH) is open when system static pressure is normal. Inspect the HPS plug on the outdoor PCB for corrosion or loose pins. | Source ↗ |
| H4 | Outdoor Low Pressure Switch (LPS) Safety Loop | Critical / Pressure Safety Circuit | Malfunction of low pressure switch (LPS) sensing circuit caused by a defective low pressure switch contact, broken lead wire in the LPS harness, loose connector contact, or a defective outdoor unit control PCB. Safe check: Isolate power before inspecting the low pressure switch harness on the suction line. Check continuity across the LPS leads while manifold gauges confirm static refrigerant pressure is above the low-pressure cutout threshold. | Source ↗ |
| JA | Outdoor Refrigerant High Pressure Sensor (Transducer) | Critical / Sensor Fault | Malfunction of outdoor high pressure sensor caused by a defective high pressure transducer, loose or oxidized connector contact, accidental swap of the low-pressure and high-pressure sensor plugs, or a defective outdoor unit PCB. Safe check: Power down the outdoor unit and verify that the high-pressure (red/high-side) and low-pressure transducer connectors are plugged into their matching color-coded headers on the outdoor PCB, and measure the 5V DC sensor reference supply. | Source ↗ |
| JC | Outdoor Refrigerant Low Pressure Sensor (Transducer) | Critical / Sensor Fault | Malfunction of outdoor low pressure sensor caused by a defective low pressure transducer, loose or oxidized connector contact, accidental connection of the high-pressure sensor plug into the low-pressure header, or a defective outdoor unit PCB. Safe check: Switch off the outdoor isolator and verify that the low-pressure (suction side) and high-pressure transducer plugs are connected to their matching color-coded headers on the outdoor PCB, and check the 5V DC sensor supply voltage. | Source ↗ |
| J1 | Outdoor Refrigerant Pressure Sensor System (Unified) | Critical / Sensor Fault | Malfunction of outdoor refrigerant pressure sensor caused by a loose or corroded pressure sensor harness connector, open/short circuit in the pressure transducer element, or a defective outdoor unit control PCB. Safe check: Isolate power at the outdoor disconnect before inspecting the pressure transducer harness for pin corrosion or moisture ingress, and compare the transducer output voltage against static manifold gauge pressure. | Source ↗ |
| J2 | Outdoor Compressor Current Sensor (CT Toroid) | Critical / Inverter Current Sensing | Malfunction of compressor current sensor caused by a defective current transformer (CT) sensor on the outdoor inverter board, open compressor phase winding, or a defective outdoor unit PCB. Safe check: Power down the outdoor isolator and wait for the DC bus capacitors to discharge completely. Verify that the compressor phase lead passes cleanly through the CT sensor core and check compressor U-V-W winding resistance balance. | Source ↗ |
| A0 | Indoor Unit External Protection Device Interlock (T1-T2) | Critical / Safety Interlock | External protection device connected to the T1-T2 interlock terminal strip of the indoor unit is activated (such as an external condensate pump overflow safety float switch, fire alarm relay, or keycard interlock). Safe check: Switch off the indoor isolator and check whether an external condensate drain pump safety switch, BMS fire relay, or factory jumper across indoor terminals T1 and T2 has opened. | Source ↗ |
| A8 | Indoor Unit Power Supply & AC Input Overcurrent | Critical / Electrical Supply | Malfunction of indoor power supply or AC input overcurrent caused by abnormal supply voltage sag/swell, defective connection on the inter-unit power/signal line, or faulty indoor wiring. Safe check: Verify 220–240V 50Hz AC supply voltage stability at the indoor terminal block and inspect the inter-unit power and signal wiring for loose screw terminals or degraded insulation. | Source ↗ |
| AJ | Indoor Unit PCB Capacity Setting Adaptor | Critical / Configuration Fault | Malfunction of indoor unit PCB capacity setting caused by failure to transfer or install the model capacity-setting resistor adaptor when replacing a spare indoor PCB, or a defective indoor unit PCB. Safe check: Power down the indoor unit after a service PCB replacement and verify that the original model-specific capacity setting adaptor plug was transferred from the old board to the new indoor PCB header. | Source ↗ |
| C1 | Indoor Unit Main PCB to Sub-PCB Internal Transmission | Critical / Internal Bus Fault | Failure of internal communication transmission between the indoor unit main control PCB and sub-PCB caused by a loose or oxidized ribbon connector between the indoor boards. Safe check: Switch off the indoor isolator and inspect the board-to-board wiring harness between the indoor main control PCB and any sub-PCB or fan driver daughterboard to ensure all pins are seated cleanly. | Source ↗ |
| C6 | Indoor Fan Motor Hall Sensor & Fan Control Driver | Critical / Fan Drive Fault | Malfunction of indoor fan motor Hall-effect position sensor or fan control driver caused by a defective indoor fan driver PCB, loose capacity setting adaptor connection, or field setting error. Safe check: Isolate power before checking the indoor BLDC fan motor Hall-IC feedback plug, verifying that the capacity-setting resistor adaptor matches the indoor model, and spinning the blower wheel by hand to rule out bearing drag. | Source ↗ |
| E8 | Outdoor Inverter Compressor Input Overcurrent | Critical / Inverter Overcurrent | Overcurrent of the outdoor inverter compressor caused by a locked or grounded compressor motor, degraded inverter main-circuit smoothing capacitor, defective power transistor (IPM), or a defective outdoor unit PCB. Safe check: Power down the outdoor isolator and wait for the high-voltage DC bus capacitors to discharge. Measure compressor U-V-W winding resistance and insulation to ground before testing the inverter IPM module. | Source ↗ |
| EA | Outdoor Four-Way Reversing Valve Solenoid & Refrigerant Circuit | High — Four-Way Valve Switching Fault | Malfunction of four-way valve or cool/heat switching caused by a defective four-way reversing valve/solenoid coil, shortage of refrigerant gas, defective outdoor unit PCB, or defective thermistor. Safe check: Switch off the isolator breaker and have a technician verify 220–240V AC output to the four-way valve solenoid coil, check refrigerant operating pressures, and test the coil thermistor. | Source ↗ |
| H5 | Outdoor Compressor Overload Protection Circuit | High — Compressor Overload Sensor Fault | Malfunction of compressor motor overload thermistor due to a defective compressor motor overload thermistor or defective connector contact on the outdoor PCB. Safe check: Isolate mains power, inspect the compressor overload thermistor connector plug on the outdoor PCB for loose pins, and test thermistor resistance against the Daikin service curve. | Source ↗ |
| L0 | Outdoor Inverter Power Module & Supply Circuit | High — Inverter System Fault | Malfunction of inverter system caused by a shortage of power supply capacity, defective power transistor (IPM) module, or defective outdoor unit inverter PCB. Safe check: Turn off the circuit breaker for 5 minutes and have a licensed technician verify incoming L-N voltage stability under load and perform an IPM diode-matrix test. | Source ↗ |
| L1 | Outdoor Inverter PCB / Power Drive Stage | High — Outdoor Inverter PCB Fault | Malfunction of inverter PCB caused by defective compressor wiring, defective outdoor unit fan motor, blown fuse, or defective inverter PCB. Safe check: Isolate mains power at the outdoor isolator for 5 minutes to discharge DC bus capacitors, inspect the outdoor inverter board fuse and U/V/W compressor phase leads, and check the outdoor fan motor harness before replacing the inverter PCB. | Source ↗ |
| L6 | Outdoor Inverter AC Output / Compressor Winding | High — Instantaneous AC Output Overcurrent | Inverter instantaneous overcurrent (AC output) caused by overcharge of refrigerant amount, shortage of power supply capacity, defective compressor, or defective inverter unit. Safe check: Verify incoming 230V AC supply stability under load, check manifold gauge pressures for refrigerant overcharge, and test compressor stator winding resistance and ground insulation before powering the inverter unit. | Source ↗ |
| LA | Outdoor Power Transistor (IPM) / Compressor Drive | High — Power Transistor Malfunction | Malfunction of power transistor caused by a defective power transistor module, defective compressor, or defective outdoor inverter PCB. Safe check: Perform a multimeter diode-drop test across the power transistor module terminals after full capacitor discharge and megger-test the compressor windings to prevent a shorted compressor from damaging a replacement inverter board. | Source ↗ |
| P3 | Outdoor Electrical Switch Box / Reactor Thermistor | Medium-High — Switch Box Thermistor Fault | Malfunction of thermistor in switch box caused by defective connection of thermistor, defective reactor thermistor, or defective outdoor inverter PCB. Safe check: Isolate outdoor mains power, allow high-voltage DC bus capacitors to discharge, inspect the reactor/switch-box thermistor connector header on the inverter PCB, and measure NTC thermistor resistance against ambient temperature. | Source ↗ |
| PJ | Outdoor Unit Main PCB / Capacity Setting & Fan Driver | High — Outdoor Capacity Setting or PCB Mismatch | Malfunction of capacity setting (Outdoor unit PCB) or improper combination between inverter and fan driver caused by missing or improper capacity setting adaptor, mismatching PCB type, improper field setting after replacing outdoor main PCB, or defective outdoor unit PCB. Safe check: Verify that the factory capacity setting adaptor plug was transferred from the original outdoor PCB to the replacement service PCB and confirm outdoor field settings match the condenser model tonnage. | Source ↗ |
| U3 | System Commissioning / Check Operation | Medium — Check Operation Not Executed | Check operation not executed or transmission error because the mandatory commissioning check operation has not been completed. Safe check: Confirm all liquid and gas stop valves are fully open, verify F1/F2 indoor-outdoor transmission continuity, and execute the mandatory test/check operation sequence from the remote controller or outdoor PCB. | Source ↗ |
| U6 | Inter-Unit Serial Communication Bus (Indoor-to-Indoor) | High — Group / Multi-FCU Communication Fault | Malfunction of transmission between indoor units caused by faulty inter-unit wiring, external electromagnetic noise, or a defective indoor unit PCB. Safe check: Switch off the isolator breaker for 5 minutes, inspect indoor-to-indoor F1/F2 daisy-chain terminal blocks for loose crimps or reversed polarity, and keep communication cables separated from 230V AC power lines. | Source ↗ |
| U7 | Outdoor-to-Outdoor / External Control Adaptor Bus | High — Inter-Condenser Bus Transmission Fault | Malfunction of transmission between outdoor units or outdoor storage unit due to a connection error on transmission wirings between the outdoor unit and external control adaptor, inter-outdoor bus wiring fault, or a defective outdoor unit PCB. Safe check: De-energize the outdoor condensers, verify Q1/Q2 or F1/F2 inter-outdoor and external control adaptor wiring continuity, and confirm proper termination resistor and address DIP switch settings. | Source ↗ |
| U8 | Main / Sub Wired Remote Controller Bus (P1-P2) | Moderate — Dual Remote Controller Link Fault | Malfunction of transmission between remote controllers caused by a transmission error between main and sub remote controllers, accidental connection between two sub remote controllers, or a defective remote controller PCB. Safe check: Verify that when two wired remote controllers share one indoor FCU on the P1/P2 bus, exactly one controller is designated as Main and the second is configured as Sub. | Source ↗ |
| U9 | Other-System Inter-Unit Bus / Shared Refrigerant Circuit | High — Other-System Transmission or EEV/PCB Fault | Malfunction of transmission in another connected system caused by a transmission error between other indoor and outdoor units, a defective electronic expansion valve or indoor PCB on another indoor unit in the same refrigerant branch, or improper indoor-outdoor transmission wiring. Safe check: Inspect all other indoor fan coil units sharing the same multi-split or VRV outdoor condenser for active fault codes, verify F1/F2 daisy-chain wiring continuity across all branch units, and reset the shared outdoor isolator for 5 minutes. | Source ↗ |
| UC | Centralized Control Address Configuration | Moderate — Centralized Control Address Duplication | Malfunction of setting of centralized control equipment address caused by duplicate centralized control group addresses (e.g. two indoor units assigned the same DIII-Net central address) or a defective indoor unit PCB. Safe check: Audit centralized group addresses (1-00 to 4-15) across all connected indoor units via the wired remote controller service menu to eliminate duplicate address assignments. | Source ↗ |
| UE | Indoor-to-Centralized Controller Bus (F1-F2 DIII-Net) | High — Centralized Control Transmission Fault | Malfunction of transmission between indoor unit and centralized control equipment due to a transmission error between optional centralized controllers and the indoor unit, a disconnected main-controller / changeover switch jumper, or a defective central remote controller or indoor PCB. Safe check: Check F1/F2 centralized control bus continuity at the indoor unit terminal strip, confirm the master centralized controller is powered on, and verify the independent/combined changeover connector is seated. | Source ↗ |
| UF | Commissioning / Refrigerant Piping & Inter-Unit Wiring | High — System Not Set / Piping-Wiring Mismatch or Stop Valve Closed | System is not set yet due to improper connection of transmission wiring between indoor-outdoor units and outdoor-outdoor units, failure to execute the commissioning check operation, a defective indoor unit PCB, or a closed liquid/gas stop valve. Safe check: Confirm both outdoor liquid and gas king stop valves are fully open, verify that each indoor FCU's F1/F2 communication pair matches its corresponding refrigerant port, and run the outdoor unit commissioning check operation. | Source ↗ |
| UH | System-Wide Inter-Unit Addressing & Bus Topology | High — System Malfunction / Cross-Connected Indoor-Outdoor Wiring | Malfunction of system caused by improper connection of transmission wiring between indoor-outdoor units and outdoor-outdoor units, a defective indoor unit PCB, or a defective outdoor unit PCB. Safe check: De-energize the system, trace F1/F2 indoor-to-outdoor and Q1/Q2 outdoor-to-outdoor communication cables for cross-connected refrigerant circuits, and inspect indoor/outdoor PCB bus transceivers. | Source ↗ |
| UJ | Peripheral / Accessory Device Serial Bus | Moderate — Accessory Device Transmission Fault | Malfunction of transmission with an optional accessory device caused by a defect in the connected accessory device (such as a drain pump kit, humidifier, or interface adaptor) or faulty accessory harness wiring. Safe check: Switch off the isolator breaker, inspect the plug-in accessory harness and KRP/DIII interface adaptor connectors on the indoor PCB, and verify accessory power supply continuity. | Source ↗ |
| E0 | Outdoor Unit Protection Circuit / Unified Safety Interlock | High — Outdoor Safety Protection Chain Actuated | Protection devices activated (unified). Supposed causes per Daikin service manual: protection device connected to outdoor unit PCB actuated, or defective protection device connector contact. Safe check: Isolate mains power for 5 minutes, inspect outdoor condenser coil and fan for airflow blockage or closed service valves, and verify closed-loop continuity across the outdoor PCB safety protection harness connector. | Source ↗ |
| J4 | Outdoor Unit Refrigerant Circuit / Low-Pressure Saturated Temperature Sensor | Medium — Outdoor Suction Saturated Temperature Thermistor Fault | Malfunction of low pressure equivalent saturated temperature sensor system. Supposed causes per Daikin service manual: defective connection of thermistor, defective thermistor, or defective outdoor unit PCB. Safe check: Power down the system, check that the low-pressure saturated temperature NTC thermistor plug is dry and seated on the outdoor PCB, verify sensor sleeve contact on the suction return pipe, and measure thermistor kΩ resistance against Daikin's R-T curve. | Source ↗ |
| J8 | Outdoor Unit Refrigerant Circuit / Liquid Pipe Thermistor | Medium — Outdoor Liquid Pipe NTC Thermistor Fault | Malfunction of thermistor (Refrigerant circuit). Supposed causes per Daikin service manual: defective connection of thermistor, defective liquid pipe thermistor, or defective outdoor unit PCB. Safe check: Isolate power, inspect the outdoor liquid distributor pipe thermistor retaining clip and harness pins for corrosion, and test NTC resistance across the sensor leads with a multimeter before replacing the thermistor or outdoor PCB. | Source ↗ |
| A4 | Indoor Unit Heat Exchanger / Freeze-Up Protection Control | Medium — Indoor Heat Exchanger Freeze Protection Actuated | Malfunction of freezing protection. Supposed causes per Daikin service manual: shortage of water volume, low water temperature setting, or defective water/heat-exchanger temperature thermistor. Safe check: Inspect indoor air filters and evaporator fins for restricted airflow, verify that the indoor heat-exchanger/water thermistor connector is firmly seated on the indoor PCB, and measure thermistor resistance across ambient temperature. | Source ↗ |
| AF | Indoor Unit Humidifier / Condensate Drain Float System | Medium — Humidifier / Drain Level Overflow Fault | Malfunction of a humidifier system. Supposed causes per Daikin service manual: humidifier unit (optional accessory) leaking, defective drain piping (upward slope, etc.), or defective indoor unit PCB. Safe check: Isolate indoor power, inspect the condensate drain hose for reverse/upward gradient or bio-slime blockage, check the humidifier/float switch harness for water shorting, and clear the drain pan before resetting. | Source ↗ |
| AH | Indoor Unit Electrostatic Air Cleaner / Dust Collector | Low — Air Cleaner High-Voltage Collector Abnormality | Malfunction of dust collector of air cleaner. Supposed causes per Daikin service manual: defect of dust collecting element, stained insulator part, defect of high voltage power supply unit, or defect of indoor unit PCB. Safe check: Switch off the isolator, remove and clean the electrostatic dust collecting element and high-voltage insulator contacts with a dry lint-free cloth, verify dry seating, and test high-voltage power supply harness continuity. | Source ↗ |
| EC | Outdoor Unit Water-Cooled Condenser / Entering Water Temperature Sensor | Medium — Entering Cooling Water Temperature Abnormality | Malfunction of entering water temperature. Supposed causes per Daikin service manual: cooling water temperature abnormality, defective outdoor unit PCB, or defective thermistor. Safe check: Verify cooling tower/chilled-water supply flow and strainer cleanliness, inspect the entering water temperature NTC thermistor connector on the outdoor PCB, and measure thermistor resistance against water temperature. | Source ↗ |
| H1 | Outdoor / Humidifier Unit Damper & Room Temperature Sensor System | Low — Humidifier Unit Damper Limit Switch or Ambient Sensor Fault | Malfunction of room temperature sensor or humidifier unit damper. Supposed causes per Daikin service manual: defective limit switch or defective damper. Safe check: Isolate power, inspect the humidifier damper actuator linkage and micro limit switch for mechanical binding or loose harness pins, and verify continuity across the limit switch contacts. | Source ↗ |
| M1 | Centralized Control System / Central Remote Controller PCB | Medium — Central Remote Controller Main PCB Hardware Fault | Malfunction of central remote controller PCB. Supposed causes per Daikin service manual: defective central remote controller PCB. Safe check: Power-cycle the central remote controller power supply for 60 seconds, inspect the F1/F2 DIII-Net terminal connections for induced voltage or ground loops, and replace the central remote controller PCB if M1 persists. | Source ↗ |
| M8 | Centralized Control System / Inter-Controller DIII-Net Transmission | Medium — Centralized Controller Inter-Unit Transmission Error | Malfunction of transmission between optional controllers for centralized control. Supposed causes per Daikin service manual: other centralized control power disconnection, centralized control reset switch ON, defective transmission wiring, or central remote controller address change. Safe check: Verify that all optional centralized controllers on the F1/F2 bus are powered ON with reset switches released, check two-core shielded transmission wiring continuity and polarity, and confirm central controller address switches have not been altered. | Source ↗ |
| MA | Centralized Control System / Optional Controller Combination & Master Config | Medium — Improper Combination of Centralized Controllers | Improper combination of optional controllers for centralized control. Supposed causes per Daikin service manual: improper combination of optional controllers for centralized control, more than one master controller is connected, faulty setting of centralized control, or defect of centralized control. Safe check: Audit all connected centralized control devices (schedule timer, central remote, unified ON/OFF controller) to ensure only one master controller is designated on the DIII-Net bus and verify DIP/selector switch settings against the Daikin combination matrix. | Source ↗ |
| MC | Centralized Control System / Central Remote Controller Address Assignment | Low — Central Remote Controller Address Duplication | Address duplication, improper setting. Supposed causes per Daikin service manual: address duplication of central remote controller. Safe check: Inspect the rotary address switches or field address configuration on each central remote controller connected to the F1/F2 bus, assign unique sequential group/controller addresses, and cycle power to re-initialize the centralized control bus. | Source ↗ |
| JE | Outdoor Unit Refrigerant Subcooling / Oil Sensor Circuit | Medium — Sub-Tank / Oil Pressure Sensor Fault | Malfunction of oil pressure sensor or sub-tank thermistor caused by defective connector contact, defective sub-tank thermistor, or defective outdoor unit PCB. Safe check: Turn off the system breaker and have a qualified technician inspect the sub-tank thermistor/oil pressure sensor connector on the outdoor PCB and measure thermistor resistance. | Source ↗ |
| JF | Outdoor Unit Heat Exchanger / Oil Level Sensor Circuit | Medium — Oil Level / Heating HEX Thermistor Fault | Malfunction of oil level sensor or heating heat exchanger thermistor caused by defective connector contact, defective heat exchanger thermistor, or defective outdoor unit PCB. Safe check: Disconnect power and have a technician verify firm seating of the heat exchanger thermistor connector on the outdoor unit PCB and test the sensor resistance. | Source ↗ |
| P2 | Outdoor Unit Commissioning & Refrigerant Charge Control | Low — Auto-Charge Flow Interlock | Automatic refrigerant charge operation stop because the outdoor unit stop valve is not opened or the valve of the refrigerant tank is closed. Safe check: Ensure the commissioning technician fully opens the outdoor unit liquid and gas stop valves and checks the external refrigerant cylinder valve before restarting charging. | Source ↗ |
| AA | Indoor Unit Auxiliary / Duct Heater Protection (26WH) | High — Heater Overheat Cutout | Indoor unit heater overheat fault triggered when thermal protector switch 26WH opens due to restricted supply airflow or a heater relay fault. Safe check: Switch off the isolator breaker immediately, inspect indoor return air filters and supply grilles for blockage, and have a licensed technician test the 26WH thermal cutout and indoor PCB relay. | Source ↗ |
| HC | Outdoor Unit Water Temperature Sensor Circuit | Medium — Sensor Circuit Fault | Malfunction of hot water temperature thermistor due to loose connector contact, open/shorted thermistor bulb, or defective outdoor unit PCB. Safe check: Isolate power and have a technician inspect the water temperature thermistor plug on the outdoor unit PCB and measure sensor resistance against the Daikin R-T table. | Source ↗ |
| P8 | Outdoor Unit Automatic Refrigerant Charging Control | Medium — Charging Freeze Protection | Heat exchanger freezing protection activated during automatic refrigerant charging operation. Safe check: Close the external refrigerant cylinder valve immediately, verify indoor fan operation and coil temperature, and restart the automatic refrigerant charging sequence from Step 1. | Source ↗ |
| P0 | Outdoor Thermal Storage Refrigerant Circuit | Medium — Thermal Storage Refrigerant Shortage | Shortage of refrigerant amount in thermal storage unit caused by refrigerant undercharge or clogged refrigerant piping. Safe check: Switch off the system and have a licensed technician inspect the thermal storage refrigerant circuit for clogged strainers/valves and verify refrigerant charge weight. | Source ↗ |
| P9 | Humidifier Unit Fan Motor / Auto-Charge Completion Indicator | Low — Humidifier Fan Fault or Auto-Charge Complete | Indicates either completion of automatic refrigerant charge operation or a malfunction of the humidifier unit fan motor due to a defective fan motor, defective outdoor PCB, broken relay harness, or loose connector. Safe check: If triggered outside commissioning mode, isolate power and have a technician inspect the humidifier fan motor relay harness and outdoor PCB connector contact. | Source ↗ |
| PA | Auto-Charge Master Cylinder / Humidifier Heater Circuit | Medium — Empty Charging Cylinder or Heater Wire Fault | Indicates either that the refrigerant cylinder of the master unit is empty during automatic refrigerant charging, or a broken wire/fault on the humidifier unit heater or thermistor. Safe check: During automatic refrigerant charging, replace the empty master refrigerant cylinder and purge the charging hose; otherwise inspect the humidifier heater element and thermistor wiring. | Source ↗ |
| PC | Outdoor Automatic Refrigerant Charging — Slave Unit 2 Cylinder Empty | Moderate — Automatic Charging Pause | Refrigerant cylinder during automatic refrigerant charging: refrigerant cylinder of slave unit 2 is empty (RA / SkyAir / VRV SM-TS3 self-diagnosis table). Safe check: Code PC is an active commissioning status alert during multi-module VRV/SkyAir automatic refrigerant charging indicating the R32/R410A cylinder connected to Slave Unit 2 is depleted. If PC appears on a residential split controller outside a service visit, switch off the 20A outdoor isolator for 5 minutes to clear any false bus latch, and book a technician if the code returns. | Source ↗ |
| PE | Outdoor Automatic Refrigerant Charging — Operation Nearly Completed | Low — Commissioning Status Notification | Automatic refrigerant charge operation nearly completed (RA / SkyAir / VRV SM-TS3 self-diagnosis table). Safe check: Code PE is a normal status prompt during Daikin automatic refrigerant charging indicating that the target refrigerant charge weight and subcooling/superheat envelope are nearly reached (transitioning shortly to P9 when complete). Do not interrupt power while the technician completes charging. | Source ↗ |
| PH | Outdoor Automatic Refrigerant Charging / Humidifier Heater & Thermistor | High — Heater / Thermistor / PCB Fault | Refrigerant cylinder during automatic refrigerant charging / humidifier heater system malfunction (Supposed causes: defective heater unit, defective connector contact, defective thermistor, or defective outdoor unit PCB). Safe check: Turn off the aircon at the main 20A isolator for 5 minutes. If PH persists on restart, do not attempt internal wiring repairs—have a qualified technician test the humidifier heater continuity, thermistor resistance curve, harness connector contacts, and outdoor unit A1P control PCB. | Source ↗ |
| HF | Thermal Storage Unit / Storage Controller Alarm | High — Thermal Storage Controller / Wiring Fault | Alarm in thermal storage unit or storage controller (Supposed causes: thermal storage group defective wiring, defective setting, or excess of thermal storage tank numbers). Safe check: Switch off the system at the main breaker for 5 minutes. If HF returns on a commercial Daikin VRV thermal storage installation, have an ACMV technician inspect the inter-unit thermal storage control bus wiring, controller DIP switch settings, and configured tank count. | Source ↗ |
| HJ | Thermal Storage Tank Water Level Detection System | High — Low Tank Water Level / Float Sensor Fault | Malfunction of thermal storage tank water level (Supposed causes: low water level, defective switch setting, water level detecting sensor failure, or defective connector contact). Safe check: Verify that the make-up water supply valve to the thermal storage tank is open. If water supply is normal, book a technician to inspect the tank water level float switch, switch settings, and outdoor/storage controller PCB connector contacts. | Source ↗ |
| 60 | Heat Reclaim Ventilator (HRV) — External Protection Device | Moderate — External Interlock / Safety Cutout | External protection device activated (Heat reclaim ventilator) (Supposed causes: actuation of external protection device, defective output signal wiring, or defective control PCB). Safe check: Code 60 indicates that an external safety contact (such as a fire damper interlock, CO2/smoke cutoff relay, or auxiliary float switch) connected to a Daikin Heat Reclaim Ventilator has opened. Check that external interlocks are normal, reset power for 5 minutes, and have a technician inspect the external input terminal wiring and HRV control PCB if Code 60 persists. | Source ↗ |
| 64 | Heat Reclaim Ventilator (HRV) — Indoor Return-Air Thermistor | Moderate — HRV Return-Air Sensor Fault | Malfunction of indoor air thermistor (Heat reclaim ventilator) (Supposed causes: defective connector contact, defective indoor air thermistor, or defective control PCB). Safe check: Switch off the HRV isolator breaker for 5 minutes. If Code 64 persists on the remote controller, book a technician to inspect the indoor return-air NTC thermistor connector on the HRV control PCB and measure thermistor resistance against Daikin's R-T curve. | Source ↗ |
| 65 | Heat Reclaim Ventilator (HRV) — Outdoor Fresh-Air Thermistor | Moderate — HRV Outdoor-Air Sensor Fault | Malfunction of outdoor air thermistor (Heat reclaim ventilator) (Supposed causes: defective connector contact, defective outdoor air thermistor, or defective control PCB). Safe check: Isolate power to the Heat Reclaim Ventilator for 5 minutes. If Code 65 returns, have an ACMV technician inspect the outdoor intake air thermistor probe for moisture corrosion or loose harness pins and test the HRV control PCB. | Source ↗ |
| 6A | Heat Reclaim Ventilator (HRV) — Motorized Damper & Limit Switch | Moderate — HRV Bypass Damper Mechanism Fault | Malfunction of damper system (Heat reclaim ventilator) (Supposed causes: defective connector contact, defective limit switch, defective damper motor, or defective control PCB). Safe check: Turn off the HRV power supply for 5 minutes before opening the service access door. Have a qualified technician verify that the heat-exchange/bypass damper blade moves freely without obstruction and test the damper limit switch, damper motor winding, and control PCB connector. | Source ↗ |
| 80 | Hydronic / Chiller / VRV Water Heat Exchanger Entering Water Temperature Thermistor | Medium-High — Entering Water Temperature Sensor Fault | Malfunction of entering water temperature thermistor: The hydronic VRV, package, or chiller controller detected an open circuit, short circuit, or out-of-range resistance signal on the entering water temperature thermistor circuit. Safe check: Inspect the entering water header insulation and strainer for condensation ingress or physical damage to the sensor lead. Having a licensed HVAC technician inspect the thermistor connector contact on the control PCB and measure the entering water NTC thermistor resistance against Daikin temperature-resistance tables is recommended. | Source ↗ |
| 81 | Hydronic / Chiller / VRV Leaving Water Temperature Thermistor or Drain Pipe Heater | High — Leaving Water Temperature Sensor or Drain Heater Fault | Malfunction of leaving water temperature thermistor or drain pipe heater: The controller detected a defective connector contact or faulty leaving water temperature thermistor (or drain pipe heater fault) on the hydronic heat exchanger outlet. Safe check: Verify that chilled or hot water circulation valves are open and the condensate drain pan heater trace line is undamaged. A qualified technician should test the leaving water thermistor connector contact, measure NTC sensor resistance at the leaving water thermowell, and verify drain pipe heater continuity. | Source ↗ |
| 94 | Heat Reclaim Ventilator (HRV) to External Fan Unit Inter-Unit Transmission Bus | Medium-High — HRV-to-Fan-Unit Communication Fault | Malfunction of transmission (between heat reclaim ventilator and fan unit): Communication between the main Heat Reclaim Ventilator (1) and the connected fan unit (2) has failed due to a defective fan unit PCB or a broken/disconnected interconnecting wire between units (1) and (2). Safe check: Confirm that dedicated circuit breakers supplying both the Heat Reclaim Ventilator and the auxiliary fan unit are switched ON. A licensed technician should inspect the interconnecting transmission wire between unit (1) and unit (2) for loose terminals or continuity breaks and test the fan unit control PCB. | Source ↗ |
| 89 | Hydronic Chiller / Package Brazed-Plate Heat Exchanger Freeze Protection Loop | Critical — Brazed-Plate Water Heat Exchanger Freezing Trip | Malfunction of brazed-plate heat exchanger freezing: The controller detected abnormally low refrigerant or leaving water temperature across the brazed-plate heat exchanger caused by a dirty heat exchanger, shortage of refrigerant amount, or a defective thermistor. Safe check: Keep the water circulating pump running if safe to prevent ice expansion inside the brazed-plate channels and inspect the water strainer for blockage. A licensed HVAC chiller technician should verify water flow rate, check refrigerant subcooling/superheat charge, and test the freeze-protection NTC thermistor. | Source ↗ |
| 8H | Hydronic / Chiller / Hot Water Loop Three-Way Mixing Valve & High-Temperature Sensor | High — Abnormal Hot Water High Temperature Trip | Abnormal hot water high temperature: Leaving or entering hot water temperature exceeded the safety limit due to a three-way valve malfunction, defective thermistor, or improper water temperature setting. Safe check: Verify the hot water setpoint on the user controller and check whether the motorized three-way mixing valve actuator is stuck in the full-heating position. A qualified technician should test the three-way valve actuator linkage, verify water temperature thermistor resistance, and recalibrate the water temperature setting. | Source ↗ |
| 90 | Chiller / Hydronic Chilled Water Flow Volume & Auxiliary Protection (AXP) Interlock | Critical — Chilled Water Shortage or AXP Interlock Fault | Abnormal chilled water quantity or abnormal AXP: Chilled water circulation volume dropped below the minimum safety threshold or the auxiliary protection device (AXP) connector is disconnected/actuated. Safe check: Check that all chilled water isolation valves are open, the expansion tank make-up water pressure is normal, and the Y-strainer is not clogged. A licensed technician should inspect the flow switch / differential pressure sensor and verify continuity across the AXP terminal harness on the chiller control PCB. | Source ↗ |
| 97 | Thermal Storage System — Thermal Storage Unit Controller & Heat Exchanger Module | High — Thermal Storage Unit Malfunction | Malfunction of thermal storage unit: The system detected an abnormality in the thermal storage unit caused by a defective thermal storage unit module, controller PCB, or internal valve/sensor assembly. Safe check: Switch the system to standard non-storage cooling mode if available and reset main power after 5 minutes. A qualified technician should inspect inter-unit communication wiring, test the thermal storage control PCB and expansion valve coils, and replace the defective thermal storage module if out of specification. | Source ↗ |
| 98 | Thermal Storage System — Secondary Brine Circulation Pump & Overcurrent Protection | High — Thermal Storage Brine Pump Overcurrent (OC) Trip | Malfunction of thermal storage brine pump: The secondary thermal storage circulation loop halted due to actuation of the thermal storage brine pump overcurrent (OC) protection relay. Safe check: Do not repeatedly reset the breaker if the brine pump trips immediately. A licensed HVAC technician should inspect the brine pump impeller and Y-strainer for mechanical seizure or slush blockage, verify glycol concentration, and megger-test the pump motor windings and overcurrent relay (OC). | Source ↗ |
| 99 | Thermal Storage System — Brine Tank Water Level & Float Switch | Medium — Thermal Storage Brine Tank Low Water Level | Malfunction of thermal storage brine tank: Ice-making or thermal discharge operation stopped due to a low water level inside the thermal storage brine tank. Safe check: Check the external sight glass on the thermal storage tank and inspect around the tank base and piping headers for visible water/brine leaks. A technician should replenish the tank to the specified operating fill mark and test the water-level float switch continuity. | Source ↗ |
| 70 | Chiller / Package Dual-Circuit System — System No. 2 Compressor Thermal Protection | Critical — System No. 2 Compressor Overheat Trip | System No. 2 Compressor overheat: Circuit 2 compressor discharge or shell temperature exceeded the safety limit due to shortage of refrigerant amount, defective connector contact on the overload/discharge thermistor harness, or internal leakage across the four-way reversing valve. Safe check: Shut down Circuit 2 and allow the compressor shell to cool for 30 minutes while verifying condenser airflow. A licensed chiller technician should check System No. 2 refrigerant subcooling/superheat charge, inspect thermistor/overload harness contacts, and test the four-way valve for hot-gas bypass leakage. | Source ↗ |
| 71 | Chiller / Package Dual-Circuit System — System No. 2 Compressor Overcurrent Protection | Critical — System No. 2 Compressor Overcurrent Trip | System No. 2 Compressor overcurrent: Circuit 2 compressor motor current exceeded the overcurrent threshold due to shortage of refrigerant amount (loss of suction gas cooling), a power winding short circuit, or a mechanically locked/defective compressor. Safe check: Do not repeatedly reset the breaker on Circuit 2. A licensed HVAC technician should megger-test the System No. 2 compressor motor windings for phase-to-ground or turn-to-turn short circuits, verify phase voltage balance, and check Circuit 2 refrigerant charge. | Source ↗ |
| 72 | Chiller / Package Dual-Circuit System — System No. 2 Condenser Fan Motor Driver | High — System No. 2 Fan Motor Overcurrent Trip | System No. 2 Fan motor overcurrent: Circuit 2 outdoor condenser fan motor drew excessive current due to defective fan motor connector contact, a seized/defective fan motor, or a defective outdoor control/driver PCB. Safe check: Isolate power and visually check whether the System No. 2 condenser fan blades spin freely without debris obstruction. A qualified technician should inspect the fan motor lead connector for corrosion or loose pins, measure fan motor winding resistance, and test the outdoor PCB fan driver output. | Source ↗ |
| 73 | Chiller / Package Dual-Circuit System — System No. 2 High Pressure Switch (HPS) Loop | Critical — System No. 2 High Pressure Switch (HPS) Actuated | System No. 2 Actuation of high pressure switch (HPS): Circuit 2 condensing head pressure exceeded the safety cutout limit due to a dirty heat exchanger, shortage of cooling water volume, clogged refrigerant piping, defective connector contact, or a defective HPS. Safe check: Inspect the Circuit 2 outdoor condenser coil for blocked airflow or check that cooling water valves and pumps are operating normally on water-cooled packages. A licensed HVAC technician should clean the heat exchanger, verify liquid-line stop valves are fully open, and test the System No. 2 HPS continuity and harness contacts. | Source ↗ |
| 74 | Chiller / Package Dual-Circuit System — System No. 2 Low Pressure Switch (LPS) Loop | High — System No. 2 Low Pressure Switch (LPS) Actuated | System No. 2 Actuation of low pressure switch (LPS): Circuit 2 suction pressure dropped below the low-pressure safety cutout threshold due to clogged refrigerant piping, defective connector contact, shortage of refrigerant gas, or a defective LPS. Safe check: Do not bypass the low-pressure switch or force-run Circuit 2 under vacuum conditions. A licensed technician should connect manifold gauges to System No. 2, inspect the filter-drier and expansion valve for restriction, leak-test the circuit for refrigerant shortage, and verify LPS switch calibration. | Source ↗ |
| 75 | Chiller / Package Dual-Circuit System — System No. 2 Low Pressure Sensor Transducer | High — System No. 2 Low Pressure Sensor Malfunction | System No. 2 Malfunction of low pressure sensor: The controller detected an open/short circuit or out-of-range voltage signal from the Circuit 2 suction low-pressure transducer caused by a defective connector contact, a defective low pressure sensor, or a defective outdoor PCB. Safe check: Reset power for 5 minutes and check whether fault code 75 reappears immediately prior to compressor startup. A qualified technician should inspect the 3-wire pressure transducer harness on System No. 2, compare transducer DC output voltage against actual manifold gauge pressure, and replace the sensor or PCB if faulty. | Source ↗ |
| 76 | Chiller / Package System No. 2 High Pressure Sensor Circuit | high | System No. 2 Malfunction of high pressure sensor — the chiller or packaged air-conditioner controller detects an open circuit, short circuit, or out-of-range transducer voltage signal on the System No. 2 high-pressure sensor input. Safe check: Do not attempt to unbraze or remove pressure transducers on a pressurized refrigerant circuit. Isolate the main power supply and have a licensed technician inspect the System No. 2 high-pressure sensor harness for defective connector contact, measure sensor resistance/voltage output against the Daikin pressure-voltage chart for a defective high pressure sensor, and test the System No. 2 control PCB. | Source ↗ |
| 77 | Chiller / Package System No. 1 Condenser Fan Interlock Circuit | high | System No. 1 Malfunction of fan inter lock — the System No. 1 condenser fan motor interlock feedback contact fails to close or drops out during operation. Safe check: Turn off the main isolator before opening the outdoor electrical switchbox. Have a qualified HVAC technician inspect the System No. 1 fan contactor auxiliary interlock relay for a defective relay contact and check the interlock feedback loop for a broken wire or loose crimp terminal. | Source ↗ |
| 78 | Chiller / Package System No. 2 Condenser Fan Interlock Circuit | high | System No. 2 Malfunction of fan inter lock — the System No. 2 condenser fan motor interlock feedback contact fails to close or drops out during operation. Safe check: Switch off the outdoor breaker and allow capacitors to discharge before inspecting the control panel. Have a licensed technician test the System No. 2 condenser fan contactor auxiliary contact for a defective relay contact and trace the System No. 2 interlock harness for a broken wire. | Source ↗ |
| 7A | Chiller / Package System No. 2 Compressor Current Sensor Circuit | high | System No. 2 Malfunction of compressor current sensor — abnormal current transformer (CT) or current sensor signal detected on the System No. 2 compressor circuit. Safe check: Switch off the main isolator and wait for DC bus capacitors to discharge before opening the System No. 2 electrical switchbox. Have a qualified HVAC technician inspect the System No. 2 current sensor (CT) harness and sensor output, test compressor winding insulation and running current, and verify the System No. 2 outdoor unit PCB. | Source ↗ |
| 7C | Chiller / Package System No. 2 Cooling Water Pump Interlock Circuit | high | System No. 2 Malfunction of pump inter lock — the cooling/chilled water pump auxiliary interlock contact connected to System No. 2 has actuated or opened. Safe check: Verify that the chilled/cooling water circulation pump is running and that pump overload relays or flow interlock switches have not tripped. Isolate power before having a licensed technician test the pump contactor auxiliary interlock contact and wiring loop to the System No. 2 controller. | Source ↗ |
| 82 | Chiller / Package System No. 1 Refrigerant Thermistor Circuit | medium | System No. 1 Malfunction of refrigerant thermistor — open circuit, short circuit, or resistance drift detected on the System No. 1 refrigerant temperature thermistor. Safe check: Power down the unit before accessing the sensor terminal block. Have a qualified technician inspect the System No. 1 refrigerant thermistor plug on the control board for defective connector contact and measure thermistor resistance against the Daikin temperature-resistance curve. | Source ↗ |
| 83 | Chiller / Package System No. 2 Refrigerant Thermistor Circuit | medium | System No. 2 Malfunction of refrigerant thermistor — open circuit, short circuit, or resistance drift detected on the System No. 2 refrigerant temperature thermistor. Safe check: Switch off the main isolator before opening the System No. 2 control box. Have a licensed technician inspect the System No. 2 refrigerant thermistor plug for defective connector contact and measure thermistor resistance against the Daikin temperature-resistance table for a defective refrigerant thermistor. | Source ↗ |
| 84 | Chiller / Package System No. 1 Heat Exchanger Thermistor Circuit | medium | System No. 1 Malfunction of heat exchanger thermistor — abnormal resistance reading, open circuit, or short circuit detected on the System No. 1 heat exchanger thermistor. Safe check: Isolate power before inspecting the heat exchanger sensor pocket. Have a qualified HVAC technician check the System No. 1 heat exchanger thermistor harness on the control PCB for defective connector contact and test the NTC probe for a defective heat exchanger thermistor. | Source ↗ |
| 85 | Chiller / Package System No. 2 Heat Exchanger Thermistor Circuit | medium | System No. 2 Malfunction of heat exchanger thermistor — abnormal resistance reading, open circuit, or short circuit detected on the System No. 2 heat exchanger thermistor. Safe check: Turn off the outdoor circuit breaker before accessing the System No. 2 sensor terminal block. Have a licensed technician inspect the System No. 2 heat exchanger thermistor connector for defective connector contact and verify sensor resistance across the operating temperature range. | Source ↗ |
| 86 | System No. 1 Compressor Discharge Pipe Thermistor Circuit (Package / Chiller) | high | System No. 1 Malfunction of discharge pipe thermistor — the System No. 1 controller detects an open-circuit, short-circuit, or out-of-range resistance signal from the compressor discharge pipe temperature thermistor on Circuit 1. Safe check: Switch off the isolator and allow the compressor discharge line to cool before inspection. Have a licensed HVAC technician inspect the System No. 1 discharge pipe thermistor lead-wire harness and board connector for loose contact or thermal insulation brittleness, and measure thermistor resistance against Daikin's R-T table before replacing the discharge pipe thermistor or control PCB. | Source ↗ |
| 88 | System No. 2 Compressor Discharge Pipe Temperature / Refrigerant Flow Protection (Package / Chiller) | critical | System No. 2 Malfunction of discharge pipe temperature — abnormal compressor discharge gas superheat or thermistor circuit fault detected on Refrigerant System No. 2 due to refrigerant shortage, clogged refrigerant piping/filter-drier, defective connector contact, or a faulty discharge pipe thermistor. Safe check: Stop System No. 2 operation immediately to prevent compressor oil carbonization and scroll/screw rotor scoring. Have a qualified technician verify Circuit 2 subcooling and superheat pressures for refrigerant shortage, check for temperature drop across the liquid-line filter-drier or expansion valve (clogged piping), and test the System No. 2 discharge pipe thermistor and PCB connector contact. | Source ↗ |
| 8A | System No. 2 Chilled Leaving Water Temperature Thermistor Circuit (Package / Chiller) | high | System No. 2 Malfunction of leaving water temperature thermistor — the System No. 2 controller detects an open or shorted thermistor signal on the chilled leaving water header sensor pocket. Safe check: Do not bypass chilled-water freeze protection interlocks. Have a licensed chiller technician inspect the System No. 2 leaving water temperature thermistor PCB connector for moisture or pin oxidation, verify thermal paste contact inside the leaving water immersion well, and test thermistor resistance across ambient and chilled water temperatures. | Source ↗ |
| 8E | System No. 1 Compressor Suction Pipe Thermistor 1 for Heating Circuit (Package / Chiller) | high | System No. 1 Malfunction of suction pipe thermistor 1 for heating — open-circuit, short-circuit, or out-of-range resistance detected on Circuit 1 suction pipe temperature thermistor No. 1 during heating/heat-pump or chiller cycle monitoring. Safe check: Isolate power before inspecting the compressor suction header. Have a qualified HVAC technician check the System No. 1 suction pipe thermistor 1 plug on the outdoor/chiller control PCB for loose pin contact or moisture ingress, verify sensor clamp seating and thermal insulation on the suction line, and compare thermistor k-ohm resistance against Daikin's R-T table. | Source ↗ |
| 8F | System No. 1 Compressor Suction Pipe Thermistor 2 for Heating Circuit (Package / Chiller) | high | System No. 1 Malfunction of suction pipe thermistor 2 for heating — open-circuit, short-circuit, or out-of-range resistance detected on Circuit 1 secondary suction pipe temperature thermistor No. 2. Safe check: Switch off the isolator before opening the electrical control box. Have a licensed technician inspect the System No. 1 suction pipe thermistor 2 harness and PCB connector for oxidation or vibration loosening, verify thermal contact on the secondary suction line pocket, and test thermistor resistance across ambient temperatures before replacing the sensor. | Source ↗ |
| 91 | System No. 2 Electronic Expansion Valve Drive Circuit (Package / Chiller) | high | System No. 2 Malfunction of electronic expansion valve — the System No. 2 controller detects a stepper-coil open/short fault or connector disconnection on the Circuit 2 electronic expansion valve (EEV). Safe check: Switch off the isolator before inspecting the Circuit 2 EEV assembly. Have a qualified HVAC technician verify that the System No. 2 EEV stator coil is firmly seated on the valve body, inspect the multi-pin PCB connector for loose contact or moisture corrosion, and measure each stepper-coil winding resistance with a multimeter. | Source ↗ |
| 92 | System No. 2 Compressor Suction Pipe Thermistor Circuit (Package / Chiller) | high | System No. 2 Malfunction of suction pipe thermistor — open-circuit, short-circuit, or out-of-range resistance detected on the System No. 2 compressor suction gas temperature thermistor. Safe check: Isolate power before opening the System No. 2 control box. Have a licensed technician inspect the Circuit 2 suction pipe thermistor PCB plug for pin oxidation or loose contact, verify sensor clip seating and closed-cell insulation on the suction header, and test thermistor resistance against Daikin's temperature-resistance curve. | Source ↗ |
| 95 | System No. 1 Fan Inverter Drive Circuit (Package / Chiller) | high | System No. 1 Malfunction of inverter system — fault detected in the System No. 1 condenser/chiller fan inverter unit. Safe check: Isolate mains power and wait at least 10 minutes for DC bus capacitors to discharge before touching the System No. 1 fan inverter board. Have a licensed technician inspect the Circuit 1 fan inverter module for thermal trip, blown fuse, or IGBT short circuit, verify fan motor winding insulation resistance, and replace the defective fan inverter unit if required. | Source ↗ |
| 96 | System No. 2 Fan Inverter Drive Circuit (Package / Chiller) | high | System No. 2 Malfunction of inverter system — fault detected in the System No. 2 condenser/chiller fan inverter unit. Safe check: Isolate mains power and allow DC link capacitors to discharge completely before inspecting the System No. 2 fan inverter module. Have a licensed chiller technician test the Circuit 2 fan motor phases for ground faults or locked bearings, inspect the System No. 2 fan inverter unit heat sink and harness connectors, and replace the defective fan inverter unit if fault persists. | Source ↗ |
| P5 | Outdoor Inverter DC Bus Current Sensor Circuit (SkyAir / VRV / Package) | high | Malfunction of DC current sensor — the outdoor inverter controller detects an abnormal offset, open circuit, or out-of-range signal from the DC link current sensor on the inverter PCB. Safe check: Switch off the outdoor isolator and wait 10 minutes for high-voltage DC bus capacitors to discharge before inspection. Have a licensed HVAC technician inspect the inverter PCB DC current sensor harness and solder joints, verify DC bus voltage balance, and replace the outdoor inverter PCB if the onboard DC current sensor is faulty. | Source ↗ |
| P6 | Outdoor Inverter AC / DC Output Current Sensor Circuit (SkyAir / VRV / Package) | high | Malfunction of AC or DC output current sensor — the outdoor inverter controller detects a zero-point drift or sensor circuit fault on the AC or DC output current sensor monitoring compressor phase current. Safe check: Isolate mains power and allow DC link capacitors to discharge before opening the inverter switch box. Have a qualified technician check the compressor U/V/W power leads for proper routing through the current sensor core, test compressor winding insulation to ground, and inspect the inverter PCB current-sensing circuit. | Source ↗ |
| P7 | Outdoor Inverter Total Input Current Sensor Circuit (SkyAir / VRV / Package) | high | Malfunction of total input current sensor — the outdoor controller detects an abnormal or missing current-transformer (CT) feedback signal on the total AC input current sensor. Safe check: Isolate power before inspecting the outdoor electrical box. Have a licensed technician check the total input current sensor (CT) connector on the inverter/main PCB for loose pins or corrosion, verify that the main supply lead passes cleanly through the CT toroid, and test CT secondary resistance. | Source ↗ |
| 9E | Chiller System No. 2 Heating Suction Pipe Thermistor 1 Circuit | medium | System No. 2 malfunction of suction pipe thermistor 1 for heating (open-circuit, short-circuit, or out-of-range temperature resistance across the primary System No. 2 heating suction line sensor input to the chiller controller PCB). Safe check: Isolate chiller main power before inspecting the System No. 2 heating suction pipe thermistor 1 harness plug on the chiller control board and checking that the sensor bulb is firmly clamped and insulated against the System No. 2 suction header. | Source ↗ |
| 9F | Chiller System No. 2 Heating Suction Pipe Thermistor 2 Circuit | medium | System No. 2 malfunction of suction pipe thermistor 2 for heating (faulty secondary heating suction line thermistor resistance value or loose connector on System No. 2 refrigerant circuit). Safe check: Power down the chiller isolator and verify that the System No. 2 heating suction pipe thermistor 2 connector is seated cleanly on the PCB without moisture ingress or damaged lead insulation; have an ACMV technician test thermistor kOhm resistance against the Daikin temperature-resistance chart. | Source ↗ |
| E2 | Outdoor Unit Earth Leakage Detection Core & Sensor Circuit | high | Missing of earth leakage detection core (the zero-phase current transformer / earth leakage detection core harness on the outdoor unit power PCB is unplugged, open-circuited, or unmounted). Safe check: Switch off the outdoor isolator breaker, wait 10 minutes for inverter DC bus capacitors to discharge, and check that the earth leakage detection core plug is securely locked into the outdoor control PCB and that the main power conductors pass cleanly through the core window. | Source ↗ |
| C0 | Indoor Unit Unified Sensor System & Thermistor Multiplexer | medium | Malfunction of sensor system (unified) (indoor unit control PCB detects a combined sensor reference voltage fault or unified thermistor/float sensor bus abnormality). Safe check: Switch off the indoor/outdoor isolator breaker and inspect the indoor unit sensor harness connectors on the control PCB for moisture, loose pins, or pinched thermistor leads before resetting power. | Source ↗ |
| C3 | Indoor Unit Condensate Drain Level Sensor Circuit | medium | Malfunction of drain level sensor (open-circuit, short-circuit, or stuck reed/thermistor drain water level sensor in the indoor unit condensate drain pan). Safe check: Isolate electrical power, remove the indoor unit service access cover, clean biological slime from the drain level float/sensor assembly and drain pan, and verify the sensor plug is firmly seated on the indoor PCB. | Source ↗ |
| C8 | Indoor Unit AC Input Current Sensor System | high | Malfunction of AC input current sensor system (abnormal zero-point offset or open/short feedback from the indoor unit AC input current transformer circuit). Safe check: Turn off the main isolator breaker, wait 5 minutes, and have a licensed technician inspect the indoor unit power/control PCB current transformer soldering and AC supply terminal tightness. | Source ↗ |
| CE | Indoor Unit Electrical Switch Box Thermistor Circuit | medium | Malfunction of switch box thermistor (open-circuit, short-circuit, or out-of-range temperature resistance from the thermistor monitoring the indoor unit electrical control box). Safe check: Switch off the isolator breaker, inspect the indoor electrical switch box ventilation slots for dust blockage, and verify that the switch box thermistor plug is firmly seated on the indoor control PCB. | Source ↗ |
| CF | Indoor Unit High Pressure Switch (HPS) Sensor Loop | high | Malfunction of high pressure switch (open-circuit or defective high-pressure safety switch contact loop monitored by the indoor unit control PCB). Safe check: Turn off main power, clean washable return-air filters to restore indoor heat-exchanger airflow, and have a licensed technician check the indoor high-pressure switch continuity and harness connector. | Source ↗ |
| H2 | Outdoor Unit Power Supply Sensor System | high | Malfunction of power supply sensor (defective voltage/phase sensing circuit or open feedback harness on the outdoor unit power supply sensor board). Safe check: Isolate the outdoor unit circuit breaker, wait 10 minutes for DC bus capacitor discharge, and have a licensed technician verify incoming 230V/400V supply voltage stability and inspect the power supply sensor PCB harness. | Source ↗ |
| HA | Outdoor Unit Discharge Air Temperature Thermistor Circuit | medium | Malfunction of discharge air thermistor (open-circuit, short-circuit, or out-of-range temperature resistance from the thermistor monitoring the outdoor unit discharge air stream). Safe check: Switch off the outdoor isolator breaker, verify that the outdoor fan discharge grille is unobstructed, and check that the discharge air thermistor plug is securely seated on the outdoor control PCB. | Source ↗ |
| HE | Outdoor Unit Drain Water Level Sensor Circuit | medium | Malfunction of drain water level sensor (faulty float switch or open/short water level sensor harness in the outdoor/humidifier drain pan circuit). Safe check: Isolate electrical power, clear any leaves or sludge blocking the outdoor base-pan drain ports, and inspect the drain water level sensor float movement and PCB connector. | Source ↗ |
| HH | Room Temperature High-Limit Alarm Circuit | high | High room temperature alarm (the monitored room/zone temperature exceeds the configured high-temperature alarm threshold or the room temperature alarm interlock is triggered). Safe check: Check whether doors/windows or external heat sources are overloading the conditioned space, clean indoor return-air filters, and verify the room thermistor calibration and alarm threshold setting on the controller. | Source ↗ |
| J0 | Outdoor Unit Thermistor Harness & Connector Routing (Outdoor Row J, Col 0) | High — Outdoor Thermistor Miswiring / Cross-Connected Sensor Fault | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row J, Column 0, Pages 1 & 2): 'Miswiring of thermistor'. Triggered when outdoor unit temperature thermistors (such as liquid pipe, gas pipe, heat exchanger, or subcooling thermistors) are cross-plugged into mismatched PCB headers or fail startup temperature-delta plausibility checks during compressor ramp-up. Safe check: Switch off the outdoor isolator for 5 minutes before opening the service panel. Only a licensed technician should verify thermistor harness colour-coding and connector keys against the outdoor PCB silkscreen diagram and measure resistance-vs-temperature curves at each thermistor plug. | Source ↗ |
| JH | Outdoor Compressor Oil Sump Temperature Sensing (Outdoor Row J, Col H) | High — Compressor Oil Temperature Thermistor Malfunction | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row J, Column H, Page 1): 'Malfunction of oil temperature thermistor'. Indicates an open circuit, short circuit, or out-of-range resistance reading on the outdoor compressor oil temperature thermistor monitoring lubricant viscosity and superheat protection. Safe check: Shut down the system at the main circuit breaker to prevent compressor bearing wear. Have a qualified HVAC technician inspect the oil temperature thermistor clip on the compressor shell, test sensor resistance with a multimeter, and inspect the outdoor main PCB sensing input. | Source ↗ |
| L7 | Outdoor Inverter Main Power Input & Current Transformer Circuit (Outdoor Row L, Col 7) | Critical — Outdoor Unit Total Input Overcurrent Trip | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row L, Column 7, Pages 1 & 2): 'Total input overcurrent'. Triggered when total AC mains input current sensed by the outdoor inverter current transformer (CT) exceeds the maximum allowable safety threshold during compressor operation. Safe check: Do not repeatedly reset the circuit breaker. Verify that outdoor condenser fins and fan discharge paths are unobstructed, then engage a licensed technician to check AC supply voltage under load, condenser fan rotation, refrigerant high-side pressure, and inverter power module integrity. | Source ↗ |
| EE | Outdoor Unit / Humidifier Condensate Drain Water Level Control Circuit (Outdoor Row E, Col E) | High — Outdoor Drain Water Level Abnormality | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row E, Column E, Page 1): 'Malfunction of drain water level'. Triggered when the outdoor unit or integrated humidifier drain pan water level float switch remains open/tripped due to blocked base-pan drainage, drain pump failure, or float switch connector fault. Safe check: Switch off the outdoor isolator breaker before inspecting the outdoor base pan and drain pan ports. Clear any sludge, leaves, or biofilm obstructing gravity drainage, and have a licensed technician check the drain level float switch continuity and outdoor PCB connector. | Source ↗ |
| EH | Outdoor Water-Cooled Condenser / Cooling Water Circulation Pump Circuit (Outdoor Row E, Col H) | Critical — Cooling Water Pump Malfunction / Interlock Trip | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row E, Column H, Page 1): 'Malfunction of cooling water pump'. Indicates an overcurrent trip, pump motor lock, or flow-interlock fault on the outdoor cooling water circulation pump. Safe check: Shut down the outdoor unit breaker immediately to prevent high-pressure condenser trip. Have a qualified ACMV technician inspect the cooling water pump contactor, thermal overload relay, strainer differential pressure, and outdoor PCB pump interlock input. | Source ↗ |
| EJ | Outdoor Unit Optional External Protection Device Interlock Circuit (Outdoor Row E, Col J) | High — Optional External Protection Device Actuated | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row E, Column J, Page 1): 'Actuation of option protection device'. Triggered when an auxiliary field-installed safety cutout (such as a fire alarm relay, external condensate float switch, or gas detector interlock) connected to the outdoor option terminal opens. Safe check: Check whether an external building fire alarm, BMS interlock, or auxiliary condensate pump cutout has tripped. If external safety conditions are normal, engage a licensed HVAC technician to test continuity across the outdoor option protection terminal block and PCB harness. | Source ↗ |
| AC | Indoor / Humidifier Water Supply & Low Water Level Cutout Circuit (Indoor Row A, Col C) | Medium — Indoor / Humidifier Stop Due to Low Water Level | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Indoor Unit Row A, Column C, Page 1): 'Stop due to low water level'. Triggered when the indoor humidifier or hydronic water level sensor detects insufficient reservoir water volume and halts operation to prevent dry-element overheating. Safe check: Verify that the make-up water supply valve is open and check the supply strainer for sediment blockage. If water supply is normal, have a licensed technician inspect the reservoir float switch and indoor PCB level sensor connector. | Source ↗ |
| AE | Indoor / Humidifier Make-Up Water Feed & Float Sensor Circuit (Indoor Row A, Col E) | Medium — Low Water Level / No Water Supply Alarm | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Indoor Unit Row A, Column E, Page 1): 'Low water level · no water supply'. Indicates that the humidifier or water-loop reservoir failed to reach normal operating level within the fill timeout window due to shut water feed valves, solenoid valve failure, or float sensor malfunction. Safe check: Check building water supply pressure and confirm the feed isolation valve is open. Engage a qualified HVAC technician to test the water feed solenoid valve coil, float switch continuity, and indoor PCB control output. | Source ↗ |
| EF | Outdoor Thermal Storage Unit Control & Heat Exchanger Circuit (Outdoor Row E, Col F) | High — Outdoor Thermal Storage Unit Malfunction | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row E, Column F, Page 1): 'Malfunction of thermal storage unit'. Triggered when the outdoor unit controller detects a protection trip, sensor fault, or interlock abnormality in the connected thermal storage unit. Safe check: Isolate power at the outdoor and thermal storage circuit breakers for 5 minutes. Have a licensed ACMV technician inspect inter-unit control wiring, thermal storage tank level/temperature sensors, and motorized valve actuators. | Source ↗ |
| 61 | Ventilation / HRV / External Control PCB & Microprocessor Circuit (Ventilation Row 6, Col 1) | High — Ventilation / Control PCB Malfunction | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column 1, Page 1): 'Malfunction of PCB'. Triggered when the ventilation/HRV or auxiliary indoor control printed circuit board fails internal self-check, EEPROM verification, or microprocessor watchdog timing. Safe check: Switch off the isolator breaker for 5 minutes to clear transient power noise and restore power. If code 61 recurs, engage a licensed HVAC technician to inspect PCB power supply voltage, wire harness connectors, and replace the defective control board. | Source ↗ |
| 62 | Indoor Air Quality / Ozone & Deodorising Element Sensing Circuit (Ventilation Row 6, Col 2) | High — Ozone Density Abnormality | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column 2, Page 1): 'Ozone density abnormal'. Indicates that the internal air-purifying or deodorising module sensor detected an out-of-range ozone concentration or high-voltage discharge fault. Safe check: Isolate unit power and ensure room ventilation is open. Have a qualified technician inspect the air-purifying electrode cartridge, clean accumulated dust from the sensor module, and verify the high-voltage power supply harness on the control PCB. | Source ↗ |
| 63 | Indoor Air Quality / Contamination & Gas Sensor Circuit (Ventilation Row 6, Col 3) | Medium — Contaminated Sensor Error | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column 3, Page 1): 'Contaminated sensor error'. Triggered when the air quality / contamination sensor output remains out of calibration range due to sensor fouling, open/short wiring, or sensor element degradation. Safe check: Clean the return-air pre-filters and ensure no silicone sprays, VOC aerosols, or heavy grease vapours are near the intake grille. If the fault persists, have a technician test the contamination sensor voltage output and PCB connector. | Source ↗ |
| 66 | Heat Reclaim Ventilator (HRV) Supply Air Damper & Intake Passage Circuit (Ventilation Row 6, Col 6) | Medium — HRV Supply Air Passage Closed Fault | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column 6, Page 1): 'Supply air passage closed'. Triggered when the Heat Reclaim Ventilator (HRV) supply air motorized shutoff damper limit switch fails to confirm an open position or the outdoor fresh-air supply passage is obstructed. Safe check: Switch off the HRV isolator breaker before inspecting the ceiling access panel. Have a licensed HVAC technician verify that the motorized supply air damper actuator linkages move freely, test the damper limit switch continuity, and clear any debris on the outdoor intake louver screen. | Source ↗ |
| 67 | Heat Reclaim Ventilator (HRV) Exhaust Air Damper & Discharge Passage Circuit (Ventilation Row 6, Col 7) | Medium — HRV Exhaust Air Passage Closed Fault | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column 7, Page 1): 'Exhaust air passage closed'. Indicates that the Heat Reclaim Ventilator (HRV) exhaust damper end-switch or airflow interlock detected a closed or blocked exhaust air discharge passage. Safe check: Isolate power to the ventilation unit and inspect the exterior exhaust weather hood for bird-mesh blockage or closed fire/backdraft dampers. Engage a qualified technician to test the exhaust damper motor and limit switch harness on the HRV control PCB. | Source ↗ |
| 68 | Heat Reclaim Ventilator (HRV) Electrostatic Dust Collection Unit Circuit (Ventilation Row 6, Col 8) | High — HRV Dust Collection Unit Malfunction | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column 8, Page 1): 'Malfunction of dust collection unit (Heat reclaim ventilator)'. Triggered when the high-voltage electrostatic dust collector module inside the Heat Reclaim Ventilator experiences an arc fault, stained insulator leakage, or high-voltage power supply abnormality. Safe check: Turn off the main isolator and wait 5 minutes for high-voltage capacitor discharge before opening the service hatch. Have a licensed technician clean the electrostatic collector plates and ceramic insulators, inspect the door interlock switch, and verify high-voltage unit output. | Source ↗ |
| 6C | Heat Reclaim Ventilator (HRV) Humidifier Element & Maintenance Timer Circuit (Ventilation Row 6, Col C) | Low — Replace the Humidify Element Maintenance Alert | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column C, Page 1): 'Replace the humidify element'. Indicates that the Heat Reclaim Ventilator (HRV) humidifying element service life counter or differential check has reached its scheduled replacement interval. Safe check: Switch off the HRV power isolator and close the make-up water valve before opening the inspection cover. Have a qualified HVAC technician inspect the pleated humidifying element for scale build-up, replace the element cartridge if calcified, and reset the maintenance timer on the remote controller. | Source ↗ |
| 6E | Heat Reclaim Ventilator (HRV) Deodorising Catalyst Filter & Timer Circuit (Ventilation Row 6, Col E) | Low — Replace the Deodorising Catalyst Maintenance Alert | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column E, Page 1): 'Replace the deodorising catalyst'. Triggered when the Heat Reclaim Ventilator (HRV) or air-purifying deodorising catalyst cartridge reaches its cumulative operating hour threshold for replacement. Safe check: Isolate power before opening the filter access panel. Vacuum the pre-filters, replace the spent deodorising catalyst cartridge per the OEM service manual, and clear the filter/catalyst maintenance sign on the wired remote controller. | Source ↗ |
| 6F | Heat Reclaim Ventilator (HRV) Simplified Remote Controller & P1/P2 Bus (Ventilation Row 6, Col F) | Medium — HRV Simplified Remote Controller Malfunction | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column F, Page 1): 'Simplified remote controller malfunction (Heat reclaim ventilator)'. Indicates a communication error, Main/Sub dip-switch conflict, or internal PCB fault on the simplified remote controller connected to the Heat Reclaim Ventilator. Safe check: Switch off the HRV breaker for 5 minutes and inspect the P1/P2 two-core remote controller terminal block for loose connections. If the fault persists, have a licensed technician verify the Main/Sub remote switch setting and test 16V DC bus continuity. | Source ↗ |
| 6H | Heat Reclaim Ventilator (HRV) Inspection Door Interlock Switch S1C (Ventilation Row 6, Col H) | Medium — HRV Inspection Door Switch Open Interlock Trip | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column H, Page 1): 'Door switch open (Heat reclaim ventilator)'. Triggered when the Heat Reclaim Ventilator (HRV) maintenance access cover interlock switch opens or loses continuity across the HRV control PCB door-switch connector, immediately halting supply and exhaust fans for technician safety. Safe check: Switch off the HRV power isolator and check that the heat-exchanger core access door is fully seated and latched so the door bracket depresses the safety plunger switch. If the door is closed and Code 6H remains active, have a licensed technician check continuity (< 0.5 Ω closed) across the door interlock microswitch and harness. | Source ↗ |
| 6J | Heat Reclaim Ventilator (HRV) High-Efficiency Filter Differential Pressure & Timer Circuit (Ventilation Row 6, Col J) | Low — Replace the High-Efficiency Filter Maintenance Alert | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Row 6, Column J, Page 1): 'Replace the high efficient filter'. Indicates that the optional high-efficiency (MERV 13 / F7–F8) pleated filter inside the Heat Reclaim Ventilator or ducted unit has reached its differential pressure switch threshold or cumulative replacement timer limit. Safe check: Isolate electrical power before opening the HRV filter service panel. Remove and replace the disposable pleated high-efficiency filter cartridge (do not wash fine synthetic filter media with water), vacuum the pre-filter mesh, and reset the filter sign on the wired remote controller. | Source ↗ |
| F4 | Outdoor Unit Liquid Refrigerant Floodback / Wet Operation & Base-Pan Protection Loop (Outdoor Row F, Col 4) | High — Outdoor Unit Wet Alarm Protection Stop | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row F, Column 4, Page 1): 'Wet alarm'. Indicates an abnormal wet-compression / liquid refrigerant floodback condition (suction superheat collapse accompanied by abnormally low discharge superheat) or an auxiliary outdoor wet alarm contact trip that stops the compressor to prevent liquid slugging. Safe check: Switch off the outdoor circuit breaker and do not repeatedly restart the compressor. Have a qualified HVAC technician inspect the electronic expansion valve (Y1E) coil and needle seating for bypass leakage, verify suction and discharge pipe thermistor readings, and confirm refrigerant charge weight. | Source ↗ |
| FA | Outdoor Unit High-Pressure Protection & HPS Cutout Loop (Outdoor Row F, Col A) | High — Abnormal High Pressure / Actuation of HPS | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row F, Column A, Pages 1 & 2): 'Abnormal high pressure, actuation of HPS'. Triggered when condensing head pressure exceeds the safety limit and trips the High Pressure Switch (S1PH) due to fouled condenser fins, stalled outdoor fan, closed stop valve, or refrigerant overcharge. Safe check: Switch off the outdoor isolator breaker and inspect the outdoor condensing unit coil fins and fan discharge grille for airflow obstructions. Have a licensed HVAC technician verify that both liquid and gas stop valves are fully open, check condenser fan operation, and measure high-side manifold pressure. | Source ↗ |
| FC | Outdoor Unit Compressor Oil Pressure Protection Circuit (Outdoor Row F, Col C) | High — Abnormal Compressor Oil Pressure Fault | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row F, Column C, Page 1): 'Abnormal oil pressure'. Indicates that net compressor oil pressure (oil pump discharge pressure minus suction crankcase pressure) has fallen below the minimum lubrication threshold or the oil pressure sensor circuit is out of range. Safe check: Turn off the outdoor circuit breaker immediately to prevent compressor bearing seizure. Have a qualified commercial HVAC technician inspect the oil pressure transducer/switch harness, verify crankcase heater operation, and check for liquid refrigerant dilution in the compressor sump. | Source ↗ |
| FE | Outdoor Unit Compressor Sump Oil Level & Return Loop (Outdoor Row F, Col E) | High — Abnormal Oil Level or Shortage of Compressor Oil | Official Daikin Split / SkyAir / VRV Fault Code Matrix (Outdoor Unit Row F, Column E, Page 1): 'Abnormal oil level or shortage of oil'. Triggered when the compressor sump optical/float oil level sensor detects low oil reserve caused by poor oil return across long refrigerant piping runs, oil trap stagnation, or refrigerant leakage carrying oil out of the circuit. Safe check: Isolate outdoor electrical power and do not force repeated restarts. Have a licensed VRV/commercial HVAC technician check compressor sight-glass/sensor oil level, verify oil-return trap geometry on vertical risers, and inspect the refrigerant circuit for leaks. | Source ↗ |
| FF | Outdoor Unit Refrigerant Oil Temperature Protection Circuit (GHP / Split / SkyAir / VRV) | high | Abnormal high temperature of refrigerant oil (Daikin Official Error Code Chart Row F, Column F). Safe check: Switch off the system and allow the outdoor unit to cool for 30 minutes. Visually inspect the outdoor condenser coil and fan discharge path for obstructions or stalled fan blades; leave compressor oil sump thermistor resistance testing, oil level inspection, and refrigerant superheat diagnostics to a licensed HVAC technician. | Source ↗ |
| FH | Outdoor Unit Engine Exhaust Temperature Protection Circuit (GHP / Split / SkyAir / VRV) | high | Abnormal exhaust temperature of engine (Daikin Official Error Code Chart Row F, Column H). Safe check: Shut down the system at the remote controller and check that the outdoor unit exhaust and condenser ventilation louvers are completely unobstructed; do not open the outdoor unit enclosure—have a qualified Daikin commercial/GHP technician inspect the exhaust gas temperature sensor, coolant circulation, and fuel-air mixture regulation. | Source ↗ |
| JJ | Outdoor Unit Engine Room & Exhaust Temperature Thermistor Circuit (GHP / Split / SkyAir / VRV) | medium | Malfunction of engine room temperature sensor or exhaust temperature (Daikin Official Error Code Chart Row J, Column J). Safe check: Turn off the outdoor isolator for 5 minutes and restart to verify if the fault clears. If Code JJ returns, do not bypass the thermal sensor harness—schedule a certified technician to measure the engine room thermistor and exhaust temperature sensor resistance curve and inspect the outdoor PCB sensor connector. | Source ↗ |
| LE | Outdoor Unit Gas Engine Igniter Circuit (GHP / Split / SkyAir / VRV) | high | Malfunction of igniter system (Daikin Official Error Code Chart Row L, Column E). Safe check: Switch off the system at the wall controller and verify that the outdoor unit service area is well ventilated and clear of obstructions; do not open the outdoor unit panel or attempt high-voltage ignition testing—engage a licensed Daikin commercial/GHP technician to inspect the ignition coil, spark plug gap, and igniter driver board. | Source ↗ |
| LF | Outdoor Unit Engine Startup Control Circuit (GHP / Split / SkyAir / VRV) | high | Engine startup error (Daikin Official Error Code Chart Row L, Column F). Safe check: Turn off the system and check that the main gas/power supply valves and outdoor ventilation louvers are open and unobstructed. Avoid repeated restart attempts that can flood or overheat the starter—have a certified Daikin technician inspect the fuel shutoff solenoid, cranking RPM sensor, and starter relay circuit. | Source ↗ |
| PF | Outdoor Unit Starter Actuation Circuit (GHP / Split / SkyAir / VRV) | high | Malfunction of starter actuation (Daikin Official Error Code Chart Row P, Column F). Safe check: Isolate outdoor unit power for 5 minutes and attempt a single clean restart. If Code PF persists, do not attempt to jump or bridge the starter contactor—schedule a qualified technician to inspect the starter magnetic switch, DC bus voltage, and outdoor main PCB starter actuation output. | Source ↗ |
| LH | Outdoor Inverter Generator Converter & Power Conditioning Module | High | Malfunction of generator converter (Outdoor Unit error matrix row L, column H). Safe check: Isolate the outdoor unit power supply, inspect the generator converter module wiring harness, DC link reactor connections, and heat-sink ventilation path for obstruction or thermal discoloration, and have an authorized Daikin engineer test the converter power stage and control PCB. | Source ↗ |
| LJ | Outdoor Prime Mover / Engine-Driven Heat Pump Actuation & Safety Interlock | High | Engine stop (Outdoor Unit error matrix row L, column J). Safe check: Record the sub-code on the remote controller, verify that fuel/power supply shutoff valves, emergency stop interlocks, and cooling/oil safety switches on the outdoor drive unit are normal, and contact a specialist Daikin service technician to inspect the prime mover starter, ignition/converter interlock, and outdoor main controller. | Source ↗ |
Engineering Reference