Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Mitsubishi Electric · Homeowner Summary + Technical Datasheet

Mitsubishi Electric Starmex R32 System 3 (MXY-3H28VG + MSXY-FP10VG)

In Plain English: Suited for Whole Flat / 2–4 Rooms, running at 19 dBA (Whisper-quiet bedroom) on low fan speed. Expect an estimated electricity bill of ~S$696/year (~S$58/month) at 8 hrs/day. Flagship 5-Tick System 3 R32 condenser MXY-3H28VG (840 × 330 × 710 mm, 55 kg net weight, 1.65 kg R32 factory pre-charge, 38.7 m³/min outdoor airflow, 49 dBA outdoor sound pressure) rated up to 6.5 kW (22,178 BTU/h) nominal cooling (1.3–8.9 kW modulation) at 1.33 kW rated power input and 5.93 A starting/running current. With 3× MSXY-FP10VG (10+10+10), delivers 2.07 + 2.07 + 2.07 = 6.20 kW nominal (2.40–8.80 kW min–max) at 1.16 kW input (0.48–2.86 kW) and 5.15 A current (2.13–12.69 A); pairing a 20-class living FCU (10+10+20) unlocks the full 6.50 kW nominal rating (1.57 + 1.57 + 3.36 kW) at 1.33 kW input and 5.90 A. Supports HDB 8.5A current-limit jumper mode (capping max input at 1.92 kW / 8.50 A and 7.10–7.20 kW max cooling) and enforces a <= 3.0 A total indoor running current limit.
Cooling Capacity
22,178 BTU/h
6.5 kW nominal
Efficiency
5.52 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$3,650
Power: ~S$696/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUMXY-3H28VG / 3× MSXY-FP10VG (10+10+10 Baseline; Supports 2–3 Indoor FCUs up to 10+10+20 / 13+13+13)
System Architecture & CompressorMulti-Split System 3 (Up to 3 FCUs) · Twin Rotary DC Inverter Compressor with PAM Control
Rated Capacity & Inverter Modulation22,178 BTU/h (6.5 kW) · Modulation: 4,436 – 30,367 BTU/h (6.20 kW Nominal on 10+10+10 · 6.50 kW Full Rated on 10+10+20 · 1.3–8.9 kW Range)
Efficiency Index & Tick StandingWCOP 5.52 W/W (NEA 5-Tick · 5.34 W/W Nominal COP on 10+10+10 · 4.89 W/W on 10+10+20) · 5
Indoor & Outdoor Sound PressureIndoor: 19 / 24 / 31 / 38 / 42 dBA (3× MSXY-FP10VG Lo-Mi1-Mi2-Hi-SHi) · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · 3× Ø6.35 mm (1/4 in) Liquid / 3× Ø9.52 mm (3/8 in) Gas Flared · 60
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Singapore — Starmex R32 Inverter Multi-Split Catalogue (MXY-3H28VG Specs & Combination Tables, Pages 20, 27 & 29) ↗
How a System 3 Aircon Connects (3 Indoor Units to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 3 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)CONNECTED #2Room 2 · Common Bedroom 2 (9K BTU)CONNECTED #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$3,177S$6,8674-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$3,955S$7,145Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$5,491S$8,241