Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
LG Electronics Troubleshooting

LG Electronics Blinking Light & Error Codes

How to check your LG Electronics code in 30 seconds: Read the 'CH' + 2-digit number on the indoor LED display, count LED blink cycles (tens + units), or run Smart Diagnosis inside the LG ThinQ mobile app. Need to check warranty status? Use the LG Electronics Serial Age Checker. (Source: LG Official Air Conditioner CH Error Code Help Library ↗)

Complete LG Electronics Fault Code Encyclopedia Table

CodePart AffectedUrgencyPlain-English Meaning & What to Try FirstManual
CH05Indoor/Outdoor CommsHigh — Communication ErrorCommunication error between indoor unit and outdoor inverter unit (also shown as CH53 or E0).
Safe check: Switch off main circuit breaker for 3 minutes, then restore power. Persistent CH05 indicates loose communication cable or outdoor PCB power fault.
Source ↗
CH01Indoor Air SensorModerate — Sensor Open/ShortIndoor return-air room temperature thermistor open or shorted (CH02 = inlet pipe sensor).
Safe check: Reset breaker for 3 minutes; if CH01 remains, indoor thermistor plug on control PCB needs reseating or replacement.
Source ↗
CH04Condensate DrainHigh — Water Overflow StopFloat switch / condensate drainage abnormality (drain pan full on cassette or pump-equipped split).
Safe check: Switch unit OFF immediately to prevent water overflow; vacuum/flush blocked PVC drain line and clean condensate pump float.
Source ↗
CH21Outdoor Inverter IPMCritical — DC Peak / OvercurrentOutdoor unit inverter compressor DC peak current or circuit board fault.
Safe check: Check that outdoor condenser coil is clear of obstructions and not overheating; book licensed technician for IPM/compressor test.
Source ↗
CH38Refrigerant ChargeHigh — Low RefrigerantRefrigerant shortage detected by abnormal suction/discharge temperature differential.
Safe check: Turn off unit and schedule flare-nut leak test and weighed R32/R410A recharge.
Source ↗
CH07Multi-Split Operating ModeLow — Mode ConflictIndoor units connected to the same multi-split outdoor condenser are set to conflicting operating modes (e.g., one room set to Cool while another is set to Heat).
Safe check: Set all active indoor wall and ceiling units on the shared outdoor condenser to the same mode (Cool, Dry, or Fan Only), then restart.
Source ↗
CH62Outdoor Inverter IPM HeatsinkHigh — Heatsink OverheatingOutdoor unit inverter Intelligent Power Module (IPM) heatsink temperature is abnormally high due to blocked airflow, fouled condenser fins, or fan failure.
Safe check: Turn off the main breaker for 5 minutes and ensure the outdoor condenser ledge has clear ventilation and unobstructed coil fins before restarting.
Source ↗
CH67Outdoor Condenser BLDC FanHigh — Outdoor Fan LockOutdoor condenser brushless DC (BLDC) fan motor rotation fault, hall sensor feedback loss, or physical fan blade obstruction.
Safe check: Switch off the outdoor isolator, inspect the outdoor fan grille for debris, and power-cycle the breaker for 5 minutes; persistent CH67 requires outdoor BLDC fan motor or PCB service.
Source ↗
CH93Indoor-Outdoor Serial LinkHigh — Inter-Unit Comms FaultCommunication failure between the indoor and outdoor controller boards on inverter split and multi-split systems.
Safe check: Turn off the main AC circuit breaker completely for 3 to 5 minutes to discharge the inverter bus and restore power; if CH93 persists, inspect the signal wire terminal block and outdoor PCB.
Source ↗
CH09Indoor Control PCB EEPROMHigh — Indoor EEPROM Memory FaultChecksum or read/write abnormality in the indoor unit control board EEPROM memory chip.
Safe check: Switch off the main AC circuit breaker completely for 3 to 5 minutes and restore power; if CH09 persists on the display, the indoor EEPROM or main PCB assembly requires technician replacement.
Source ↗
CH12Indoor Evaporator Middle Pipe SensorModerate — Indoor Coil Middle Thermistor FaultOpen or short circuit detected in the indoor heat-exchanger (evaporator) intermediate/middle pipe temperature sensor.
Safe check: Power-cycle the main circuit breaker for 3 minutes; persistent CH12 requires testing the indoor evaporator middle pipe thermistor resistance and PCB connector.
Source ↗
CH41Outdoor Inverter Compressor Discharge SensorHigh — Compressor Discharge Thermistor FaultAbnormality (open, short circuit, or unseated sensor bulb) in the outdoor inverter compressor discharge pipe temperature sensor.
Safe check: Turn off the outdoor isolator for 5 minutes and restart; if CH41 returns, have a technician verify the discharge thermistor seating on the compressor discharge tube and test sensor resistance.
Source ↗
CH44Outdoor Intake Air SensorModerate — Outdoor Ambient Air Thermistor FaultAbnormality (open or short circuit) in the outdoor unit ambient air temperature thermistor.
Safe check: Switch off the main breaker for 3 to 5 minutes; if CH44 remains active, inspect and replace the outdoor ambient air thermistor harness connected to the outdoor PCB.
Source ↗
CH66Multi-Split Inter-Unit Comms & Piping LinkHigh — Communication Line or Piping Cross-Connection FaultAbnormality detected in the communication line or mismatched refrigerant piping connections between indoor and outdoor units on inverter multi-split systems.
Safe check: Common immediately after installation or relocation; power-cycle the breaker for 5 minutes to rule out a transient glitch, then have the installer verify that each room's signal cable matches its corresponding refrigerant valve port.
Source ↗
CH03Wired Remote Controller LinkModerate — Indoor-to-Wired Controller Comms FaultCommunication error between the indoor fan coil unit main PCB and the wall-mounted wired remote controller.
Safe check: Switch off the main AC circuit breaker for 3 minutes and check that the 3-core wired remote control cable is firmly seated; if CH03 persists, inspect the wired remote harness for continuity or replace the controller.
Source ↗
CH24Outdoor High/Low Pressure SwitchHigh — Outdoor Pressure Switch FaultAbnormality or open circuit triggered by the outdoor refrigerant pressure switch due to excessive high pressure, low suction pressure, or switch harness failure.
Safe check: Turn off the outdoor isolator for 5 minutes, verify that the outdoor condenser coil fins are clean and unobstructed, and schedule a technician manifold gauge and pressure-switch continuity check.
Source ↗
CH27Outdoor Inverter PFC CircuitHigh — Power Factor Correction (PFC) Circuit FaultOvercurrent, overvoltage, or hardware fault detected in the outdoor inverter Power Factor Correction (PFC) reactor and switching circuit.
Safe check: Switch off the main isolator breaker for 5 minutes to discharge the DC bus capacitors and restart once; persistent CH27 requires outdoor inverter PCB and PFC reactor inspection.
Source ↗
CH45Outdoor Condenser Pipe SensorModerate — Outdoor Heat Exchanger Thermistor FaultAbnormality (open or short circuit) in the outdoor unit heat-exchanger (condenser coil) temperature sensor.
Safe check: Power-cycle the main circuit breaker for 3 to 5 minutes; if CH45 reappears, have a technician measure the outdoor condenser coil thermistor resistance and check its PCB plug.
Source ↗
CH46Outdoor Compressor Suction SensorModerate — Compressor Suction Pipe Thermistor FaultAbnormality (open or short circuit) in the outdoor inverter compressor suction gas pipe temperature sensor.
Safe check: Turn off the main AC breaker for 5 minutes and restart; if CH46 remains active, inspect the suction pipe thermistor bulb seating and replace the sensor harness.
Source ↗
CH28Outdoor Inverter DC Link BusHigh — Outdoor DC Link Overvoltage FaultExcessive DC link voltage detected across the outdoor inverter main capacitor bus due to supply voltage surges or regenerative braking spikes.
Safe check: Switch off the main AC isolator breaker for 5 minutes to discharge the inverter DC bus and restart once; if CH28 recurs, have a technician check incoming 230V supply stability and inspect the outdoor inverter PCB voltage-sensing resistor network.
Source ↗
CH29Outdoor Inverter Compressor DriveHigh — Compressor Overcurrent FaultExcessive phase current drawn by the outdoor inverter compressor due to liquid slugging, high discharge head pressure, seized compressor bearings, or IPM drive failure.
Safe check: Turn off the outdoor isolator for 5 minutes, ensure outdoor condenser coil fins are clean and unobstructed, and restart; persistent CH29 requires compressor winding resistance and outdoor IPM board testing.
Source ↗
CH39Outdoor Main-to-Inverter PCB LinkHigh — Internal Outdoor PCB Communication FaultCommunication failure between the outdoor unit main control PCB and the outdoor inverter compressor drive PCB.
Safe check: Switch off the main AC circuit breaker completely for 5 minutes and restore power; if CH39 persists, a technician must inspect the internal board-to-board wiring harness and DC power supply on the outdoor inverter assembly.
Source ↗
CH40Outdoor Current Transformer (CT) SensorHigh — Outdoor CT Current-Sensing Circuit FaultAbnormality (open, short, or zero-point drift) detected in the outdoor inverter Current Transformer (CT) current-sensing circuit.
Safe check: Power-cycle the main isolator breaker for 5 minutes; if CH40 returns immediately on compressor startup, the outdoor inverter PCB current transformer circuit requires technician replacement.
Source ↗
CH65Outdoor Inverter IPM ThermistorModerate — Outdoor Heatsink Thermistor FaultOpen or short circuit detected in the outdoor Intelligent Power Module (IPM) heatsink temperature sensor.
Safe check: Turn off the main AC breaker for 5 minutes and restart; if CH65 remains active, have a technician measure the outdoor IPM heatsink thermistor resistance or replace the outdoor inverter PCB.
Source ↗
CH22Outdoor AC Input CurrentHigh — Outdoor AC Input Overcurrent FaultExcessive alternating current (AC) input draw detected on the outdoor condensing unit primary supply circuit.
Safe check: Switch off the outdoor isolator breaker for 5 minutes, ensure outdoor condenser coil fins are clean and ventilated, and restart once; persistent CH22 requires checking supply voltage, compressor current draw, and the outdoor inverter board.
Source ↗
CH23Outdoor Inverter DC Link BusHigh — Outdoor DC Link Undervoltage FaultInsufficient DC link voltage detected across the outdoor inverter main capacitor bank after pre-charge or during compressor operation.
Safe check: Turn off the main AC circuit breaker for 5 minutes and restore power; if CH23 returns, have a technician measure incoming 230V AC supply under load and inspect the outdoor bridge rectifier, pre-charge relay, and DC bus capacitors.
Source ↗
CH25Outdoor Main Power SupplyModerate — Abnormal AC Supply Voltage (Out of Range)Incoming AC line voltage supplied to the outdoor unit is abnormally high or low outside the permissible inverter operating window.
Safe check: Reset the main AC breaker for 5 minutes once household power stabilizes; if CH25 persists during normal grid conditions, have a licensed technician verify terminal block voltage and outdoor PCB voltage-detection circuitry.
Source ↗
CH51Multi-Split System Capacity MatchingHigh — Over-Capacity / Indoor-Outdoor Configuration MismatchTotal connected indoor fan coil unit capacity exceeds the allowable combination limit of the outdoor condensing unit or model configuration jumpers are mismatched.
Safe check: Common immediately after new installation or PCB replacement; power-cycle the main breaker for 5 minutes and have the installer verify indoor FCU capacity combinations and outdoor PCB dipswitch settings.
Source ↗
CH60Outdoor Control PCB EEPROMHigh — Outdoor EEPROM Checksum FaultChecksum or read/write abnormality in the outdoor condensing unit main control board EEPROM memory chip.
Safe check: Switch off the outdoor isolator breaker completely for 5 minutes and restart; if CH60 reappears immediately, the outdoor EEPROM chip or outdoor main PCB assembly requires technician replacement.
Source ↗
CH06Indoor Evaporator Outlet Pipe SensorModerate — Indoor Coil Outlet Thermistor FaultAbnormality (open or short circuit) in the indoor unit heat-exchanger (evaporator) outlet pipe temperature sensor.
Safe check: Switch off the main AC circuit breaker for 3 to 5 minutes and restore power; if CH06 persists, have a technician inspect the indoor coil outlet thermistor plug on the PCB and measure sensor resistance.
Source ↗
CH35Outdoor Main-to-Sub PCB Link / Low PressureHigh — Outdoor Sub-PCB Comms or Low Suction Pressure FaultCommunication error between the outdoor main control board and secondary sub-board (or abnormally low suction pressure detected on Multi V / multi-split systems).
Safe check: Turn off the outdoor isolator for 5 minutes and restart; if CH35 returns, a technician must verify refrigerant suction pressure with manifold gauges and inspect the outdoor main-to-sub PCB harness.
Source ↗
CH52Outdoor Sub-to-Main PCB Serial LinkHigh — Secondary-to-Main Board Communication FaultCommunication packet loss from the secondary inverter sub-PCB back to the primary outdoor controller board.
Safe check: Power-cycle the main AC isolator breaker for 5 minutes to reset the outdoor boards; persistent CH52 requires inspecting internal board interconnect cables or replacing the outdoor PCB.
Source ↗
CH54Power Supply Phase SequenceHigh — Reverse Phase or Missing Phase DetectionAbnormality in cyclic phase rotation (reverse phase or open phase) detected on the main power supply after electrical works or a grid outage.
Safe check: Switch off the AC circuit breaker for 5 minutes and restart; if CH54 occurred immediately after electrical distribution board works, have an EMA-licensed electrician correct the phase sequence at the isolator.
Source ↗
CH63Outdoor Heat Exchanger TemperatureModerate — Outdoor Condenser Coil Low-Temperature FaultAbnormality or excessive sub-cooling / freezing condition detected on the outdoor unit heat exchanger.
Safe check: Turn off the main AC breaker for 5 minutes, ensure indoor air filters and outdoor coil fins are clean, and restart; if CH63 recurs, book a refrigerant charge and expansion valve inspection.
Source ↗
CH33Secondary Compressor Discharge TemperatureHigh — Secondary Compressor Overheating ProtectionAbnormally high discharge gas temperature detected on the secondary compressor in multi-compressor outdoor condensing units.
Safe check: Switch off the outdoor isolator for 10 minutes to allow the compressor shell to cool, verify outdoor condenser coil airflow, and schedule a technician refrigerant charge and expansion valve inspection.
Source ↗
CH36Refrigerant Cycle Charge MonitorHigh — Refrigerant Leakage / Low Charge DetectedAutomatic refrigerant leak detection triggered when evaporator/condenser pipe temperature differentials fail to reach target values during compressor operation.
Safe check: Power-cycle the main AC circuit breaker for 5 minutes once to rule out a transient sensor latch; if CH36 returns, confirm service valves are open and book a nitrogen pressure leak test before recharging.
Source ↗
CH42Outdoor Low-Pressure TransducerHigh — Low-Pressure Sensor Circuit FaultAbnormality (open circuit, short circuit, or out-of-range voltage) detected in the outdoor refrigerant low-pressure sensor circuit.
Safe check: Turn off the outdoor isolator breaker for 5 minutes and restart; persistent CH42 requires checking the low-pressure transducer 3-pin harness plug on the outdoor PCB and verifying suction pressure.
Source ↗
CH43Outdoor High-Pressure TransducerHigh — High-Pressure Sensor Circuit FaultAbnormality (open circuit, short circuit, or out-of-range voltage) detected in the outdoor refrigerant high-pressure sensor circuit.
Safe check: Switch off the main AC circuit breaker for 5 minutes and restart; if CH43 recurs, a technician must inspect the high-pressure sensor connector on the outdoor control board or replace the transducer.
Source ↗
CH73Outdoor Inverter AC Input StageHigh — Instantaneous AC Input Overcurrent FaultInstantaneous AC input overcurrent trip detected on the outdoor inverter primary power stage.
Safe check: Turn off the main isolator breaker for 5 minutes to discharge the inverter capacitor bank and restart once; if CH73 persists, have a technician inspect the outdoor inverter PCB, reactor, and compressor windings.
Source ↗
CH34Tertiary Compressor / High-Temp ProtectionHigh — Tertiary Compressor or Coil Overheating FaultAbnormally high discharge gas temperature on the third compressor in multi-compressor outdoor units (or excessive indoor coil temperature protection during heating operation).
Safe check: Switch off the main AC breaker for 5 to 10 minutes, clean indoor air filters and verify outdoor condenser ventilation, then restart; persistent CH34 requires technician refrigerant and sensor inspection.
Source ↗
CH47Secondary Compressor Suction SensorModerate — Secondary Compressor Suction Thermistor FaultAbnormality (open or short circuit) in the secondary compressor suction gas pipe temperature sensor on multi-compressor outdoor units.
Safe check: Turn off the outdoor isolator breaker for 5 minutes and restart; if CH47 remains active, have a technician test the secondary compressor suction thermistor resistance and PCB plug.
Source ↗
CH48Tertiary Compressor Suction SensorModerate — Tertiary Compressor Suction Thermistor FaultAbnormality (open or short circuit) in the third compressor suction gas pipe temperature sensor on multi-compressor outdoor units.
Safe check: Power-cycle the outdoor isolator breaker for 5 minutes; if CH48 reappears, inspect the tertiary suction pipe thermistor harness and replace the defective sensor.
Source ↗
CH90Test-Run Commissioning & Piping CheckHigh — Test-Run Piping or Connection AbnormalityProtective fault triggered during test-run commissioning when refrigerant circulation or inter-unit piping/valve connections fail verification.
Safe check: Common immediately after installation or relocation; switch off the breaker for 5 minutes, confirm all outdoor service valves are fully open, and have the installer verify piping and signal connections.
Source ↗
CH105Outdoor Main-to-Fan Driver PCB LinkHigh — Main PCB to Fan Board Communication FaultCommunication error between the outdoor unit main controller PCB and the brushless DC (BLDC) fan motor driver PCB.
Safe check: Switch off the main AC isolator breaker completely for 5 minutes to discharge the inverter bus and restart; persistent CH105 requires inspecting the internal fan-board communication harness or replacing the outdoor fan PCB.
Source ↗
CH37Refrigerant Cycle Compression RatioHigh — Abnormal Compression Ratio / Refrigerant ShortageAbnormal compression ratio or refrigerant leakage condition detected by the outdoor cycle monitor during compressor operation.
Safe check: Switch off the main AC circuit breaker for 5 minutes and restart once; if CH37 returns, confirm outdoor service valves are open and book a nitrogen pressure test and refrigerant charge check.
Source ↗
CH91Test-Run Refrigerant Flow & EEV CheckHigh — Commissioning Piping or Expansion Valve FaultProtective fault displayed during test-run commissioning when refrigerant flow or electronic expansion valve (EEV) response fails verification.
Safe check: Turn off the main breaker for 5 minutes, ensure all outdoor liquid/gas service valves are open, and have the installer verify EEV coil plugs and room-to-port piping assignments.
Source ↗
CH237Dual-Power-Cord Outdoor Supply LinkHigh — Outdoor Power Disconnected or Inter-Unit Link LossOn post-2021 LG inverter models equipped with separate indoor and outdoor power cords, the outdoor unit is not receiving AC power or communication is interrupted.
Safe check: Verify that the outdoor unit power plug is plugged directly into a dedicated wall socket (never a multi-plug extension strip) and that the outdoor isolator breaker is switched ON, then power-cycle for 5 minutes.
Source ↗
CH238Dual-Power-Cord Inter-Unit Serial LinkHigh — Separate-Power Indoor/Outdoor Comms FaultCommunication failure between separately powered indoor and outdoor units on post-2021 LG inverter split systems.
Safe check: Confirm both indoor and outdoor power supplies and circuit breakers are active, switch both off for 5 minutes to reset the serial bus, and have a technician inspect the inter-unit signal cable if CH238 persists.
Source ↗
COAuto Clean Evaporator Coil DryingLow — Normal 30-Min Coil Drying Status (Not a Fault)Status indicator for Cleaning Operation (Auto Clean)—runs the indoor fan for up to 30 minutes after cooling is turned off to dry the evaporator coil and prevent mould and odours.
Safe check: Normal hygiene cycle—allow the unit to finish drying for 30 minutes (after which it shuts off automatically), or toggle the Auto Clean function on the infrared remote if you wish to end it early.
Source ↗
CH10Indoor Fan Motor & Hall IC FeedbackMedium — Indoor Blower Lock / Feedback FaultIndoor unit BLDC fan motor lock or abnormal Hall IC rotation feedback (displayed as CH10 or E6 on select LG split systems).
Safe check: Switch off the circuit breaker for 5 minutes and inspect the indoor cross-flow blower wheel for physical obstructions or debris before requesting service.
Source ↗
CH53Indoor-Outdoor Serial Communication BusHigh — Communication Signal LossCommunication error between the indoor and outdoor inverter PCB assemblies (grouped with CH05 / E0 communication faults).
Safe check: Turn off the circuit breaker and wait 5 full minutes to reset transient electrical noise; if triggered after installation, have the technician inspect interconnect communication wiring.
Source ↗
CH61Condenser / Heat Exchanger Thermal ProtectionHigh — Condenser Coil High Temperature CutoutOutdoor unit condenser coil overheating during cooling mode (or indoor heat exchanger overheating during heating mode) due to restricted airflow or heat recirculation.
Safe check: Open enclosed aircon ledge louvers, clear any obstacles blocking outdoor condenser discharge airflow, clean dusty indoor air filters, and cycle the breaker off for 5 minutes.
Source ↗
CH26Outdoor Inverter Compressor DC IPM / Position DriveCritical — Outdoor Compressor / PCB FaultOutdoor unit inverter compressor DC overcurrent, rotor position detection, or outdoor main circuit board drive fault.
Safe check: Perform a 5-minute power reset at the circuit breaker; if CH26 recurs, keep the system off and schedule an LG or NEA-licensed technician to test compressor winding resistance and the outdoor PCB.
Source ↗
CH02Indoor Evaporator Inlet Pipe Thermistor SensorMedium — Pipe Temperature Sensor Open / ShortIndoor unit inlet pipe temperature sensor (thermistor) fault, loose connector, or main PCB sensor read error (also displayed as E1 on select LG room units).
Safe check: Unplug the unit or switch off the circuit breaker for 5 minutes and restore power; if CH02 persists, book a technician to measure the indoor pipe thermistor resistance and inspect the PCB connector.
Source ↗
E9Outdoor Compressor Drive & Protection CircuitCritical — Outdoor Compressor / Control Circuit FaultOutdoor unit compressor drive, protection circuit, or outdoor control board fault (grouped with CH21, CH23, CH26, and CH29 compressor/PCB protection alarms).
Safe check: Switch off the circuit breaker for 5 minutes to clear temporary voltage spikes; if E9 reappears, leave the unit off and schedule an authorized technician to inspect the outdoor compressor and inverter board.
Source ↗
E1Indoor Room / Pipe Temperature Sensor CircuitMedium — Indoor Thermistor Sensor FaultIndoor temperature or pipe thermistor sensor open/short circuit, loose sensor harness, or main circuit board sensor read fault (paired with CH01/CH02 sensor diagnostics).
Safe check: Unplug the air conditioner or switch off the circuit breaker for 5 minutes to clear temporary electrical glitches; if E1 persists, schedule a technician to inspect the thermistor sensor harness.
Source ↗
F2Evaporator / Condenser Temperature Sensor CircuitMedium — Temperature / Pipe Sensor FaultSelf-diagnostic temperature or pipe thermistor sensor fault caused by a defective sensor bead, loose PCB connector, or control board input error.
Safe check: Perform a 5-minute power reset at the circuit breaker; if F2 reappears, stop operating the unit and have a service technician test sensor resistance and PCB continuity.
Source ↗
E0Indoor-Outdoor Serial Communication BusHigh — Communication Signal LossCommunication error between the indoor and outdoor inverter PCB assemblies (grouped with CH05 and CH53 communication faults).
Safe check: Unplug the power cord or turn off the circuit breaker for 5 full minutes and restore power; if E0 persists, have a technician inspect the indoor-outdoor communication line and PCB.
Source ↗
F4Refrigerant Charge & Piping CircuitHigh — Low Refrigerant / Test Run Piping ProtectionRefrigerant shortage (low gas) or piping connection abnormality detected by the self-diagnostic system (paired with CH38/CH90/CH91 protection alarms).
Safe check: Switch off the circuit breaker for 5 minutes to rule out transient voltage drops; if F4 reappears, book an NEA-licensed technician to inspect flare joints and verify refrigerant pressure.
Source ↗
EFOutdoor Condenser Fan Motor & Blade AssemblyHigh — Outdoor Fan Motor Lock / Feedback FaultOutdoor unit condenser fan motor rotation or feedback fault (grouped with CH67 outdoor fan errors).
Safe check: With the circuit breaker switched off, check for debris obstructing the outdoor condenser fan blades; if clear and EF persists after a 5-minute reset, schedule outdoor fan motor/PCB service.
Source ↗