Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Mitsubishi Electric · Homeowner Summary + Technical Datasheet

Mitsubishi Electric Starmex R32 Hybrid 7.1 kW Slim Concealed Ducted + Wall System 4 (MXY-4H33VG / 1× SEZ-M71DAL Ducted + 3× MSXY-FP10VG Wall)

In Plain English: Suited for Whole Flat / 2–4 Rooms, running at 19 dBA (Whisper-quiet bedroom) on low fan speed. Expect an estimated electricity bill of ~S$742/year (~S$62/month) at 8 hrs/day. Complete hybrid System 4 pairing the compact 4-port MXY-4H33VG R32 inverter outdoor condenser (6.9 kW rated / 1.3–10.7 kW modulation, 1.42 kW rated power input, 6.37 A outdoor running current, 38.7 m³/min outdoor airflow, 49 dBA outdoor sound pressure, 840×330×710 mm, 56 kg, 1.85 kg R32 pre-charge, 60 m max total / 25 m per-unit piping length) with one SEZ-M71DAL ultra-slim 200 mm high-capacity ceiling-concealed ducted unit (7.1 kW rated / 1.7–8.5 kW range, 1,190×700×200 mm, 25.5 kg, selectable 5 / 15 / 35 / 50 Pa static pressure, 12.0–16.0–20.0 m³/min airflow, 30–35–40 dBA sound pressure at 15 Pa, 0.10 kW input, 0.84 A max running current, optional PAC-KE07DM-E 550 mm drain lift pump) for an open-concept living/dining zone and three MSXY-FP10VG wall-mounted fan coil units (3× 2.8 kW, 3× 0.27 A = 0.81 A) for bedrooms. Total combined indoor running current is 1.65 A (0.84 A + 0.81 A), ideal for apartments with tight 840×330×710 mm condenser ledge constraints that require 20.0 m³/min living-room airflow during daytime operation and quiet bedroom cooling at night (Catalogue Pages 3, 20 & 23).
Cooling Capacity
23,543 BTU/h
6.9 kW nominal
Efficiency
5.5 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$5,680
Power: ~S$742/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUMXY-4H33VG / 1× SEZ-M71DAL (7.1 kW Slim 200 mm Ducted) + 3× MSXY-FP10VG (2.8 kW Wall)
System Architecture & CompressorMulti-Split System 4 (Hybrid Slim Ceiling-Concealed Ducted + Wall-Mounted) · Twin Rotary DC Inverter (PAM Control)
Rated Capacity & Inverter Modulation23,543 BTU/h (6.9 kW) · Modulation: 4,436–36,508 BTU/h (1.3–10.7 kW)
Efficiency Index & Tick StandingWCOP 5.50 (NEA 5 Ticks) · 5
Indoor & Outdoor Sound PressureIndoor: 30 / 35 / 40 dBA at 15 Pa (SEZ-M71DAL Ducted) & 19 / 24 / 29 / 36 / 45 dBA (MSXY-FP10VG Wall) · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · 6.35 mm (1/4 in) liquid × 4 / 12.70 mm (1/2 in) gas on Port A (flared reducer to SEZ-M71DAL 9.52/15.88 mm) + 9.52 mm (3/8 in) gas × 3 · 60
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Singapore — Starmex R32 Multi-Split Catalogue (MXY-4H33VG Hybrid SEZ-M71DAL Slim Ducted + MSXY-FP Series, Pages 3, 20 & 23) ↗
How a System 4 Aircon Connects (4 Indoor Units to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 4 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)CONNECTED #2Room 2 · Common Bedroom 2 (9K BTU)CONNECTED #3Room 3 · Study / Bedroom 3 (9K BTU)CONNECTED #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$3,372S$7,0624-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$4,198S$7,388Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$5,829S$8,579