Mitsubishi Electric · Homeowner Summary + Technical Datasheet
Starmex R32 System 4 (MXY-4H33VG + 1× MSXY-FP10VG + 3× MSXY-FP13VG — 9K Study + Three 12K Bedrooms Package)
Cooling Capacity
22,178 BTU/h
6.5 kW nominal
Efficiency
5.44 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$4,420
Power: ~S$707/yr
Complete Technical Encyclopedia Datasheet
| Outdoor / Indoor Unit SKU | MXY-4H33VG / 1× MSXY-FP10VG + 3× MSXY-FP13VG |
|---|---|
| System Architecture & Compressor | Multi-Split System 4 (4-Bedroom / Executive HDB & Condo 1× 9K + 3× 12K All-Bedroom Wall Package) · DC Twin Rotary Inverter with PAM Control & New LEV Control |
| Rated Capacity & Inverter Modulation | 22,178 BTU/h (6.5 kW) · Modulation: 8,871–30,367 BTU/h (Standard) / 8,871–24,566 BTU/h (8.5A HDB Mode) |
| Efficiency Index & Tick Standing | NEA 5-Tick (WCOP 5.44 / Nominal 4-Room COP 5.00 at 6.50 kW Cooling / 1.30 kW Input) · 5 |
| Indoor & Outdoor Sound Pressure | Indoor: 19–45 dBA (1× FP10VG Study) / 19–47 dBA (3× FP13VG Bedrooms) · Outdoor Condenser: 49 dBA |
| Refrigerant, Copper Pipe Size & Max Span | R32 · Liquid: 4× Ø6.35 mm (1/4") / Gas: 3× Ø9.52 mm (3/8" native) + 1× Ø12.70→Ø9.52 mm on Port D via PAC-SG76RJ-E flare reducer · 60 |
| Troubleshooting & Age Lookup | Mitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker |
| Verified Manufacturer Datasheet | Mitsubishi Electric Starmex R32 Inverter Multi-Split Catalogue (Pages 20, 27 & 29 — MXY-4H33VG 4-Room 10+13+13+13 Standard & 8.5A Specs) ↗ |
Engineering Reference