Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Mitsubishi Electric · Homeowner Summary + Technical Datasheet

Mitsubishi Electric Starmex System 3 R32 Inverter (8.5A HDB Current-Limited — MXY-3H28VG / 2× MSXY-FP10VG + 1× MSXY-FP20VG)

In Plain English: Suited for Whole Flat / 2–4 Rooms, running at 19 dBA (Whisper-quiet bedroom) on low fan speed. Expect an estimated electricity bill of ~S$786/year (~S$66/month) at 8 hrs/day. Official Mitsubishi Electric Starmex R32 Catalogue (Pages 20 & 29) 8.5A HDB current-limited System 3 pairing outdoor unit MXY-3H28VG (8.5A) (840×330×710 mm, 55 kg, 38.7 m³/min outdoor airflow, 49 dBA, 1.65 kg R32 pre-charge, 60 m max total piping / 25 m single FCU) with 3× MSXY-FP10VG bedroom wall units (3× 2.07 = 6.20 kW nominal cooling, 2.40–7.10 kW min-max, 1.16 kW nominal / 0.48–1.92 kW min-max power input, and 5.15 A nominal / 2.13–8.50 A capped running current for older HDB 8.5A isolator circuits).
Cooling Capacity
22,178 BTU/h
6.5 kW nominal
Efficiency
4.89 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$3,450
Power: ~S$786/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUMXY-3H28VG (8.5A HDB Mode) / 2× MSXY-FP10VG + 1× MSXY-FP20VG
System Architecture & CompressorMulti-Split System 3 (8.5A HDB Current-Limited Wall-Mounted Package) · Twin Rotary DC Inverter Compressor (8.5A Current-Limited)
Rated Capacity & Inverter Modulation22,178 BTU/h (6.5 kW) · Modulation: 8,189–24,225 BTU/h (6.20 kW nominal / 2.40–7.10 kW min-max for 3× FP10VG; 1.16 kW nominal / 0.48–1.92 kW max power input; 8.50 A max current cap)
Efficiency Index & Tick StandingNEA 5-Tick Multi-Split (4.89 Rated COP in 10+10+20 8.5A Mode) · 5
Indoor & Outdoor Sound PressureIndoor: 19 – 45 dBA (FP10VG) / 30 – 50 dBA (FP20VG) · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · 3× Ø6.35 mm Liquid / 3× Ø9.52 mm Gas · 60
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Singapore — Starmex R32 Catalogue (MXY-3H28VG 8.5A HDB Current-Limited Combination Table, Pages 20 & 29) ↗
How a System 3 Aircon Connects (3 Indoor Units to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 3 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)CONNECTED #2Room 2 · Common Bedroom 2 (9K BTU)CONNECTED #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$3,177S$6,8674-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$3,955S$7,145Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$5,491S$8,241
Engineering Reference

Technical Schematic

Singapore HDB 8.5A vs Uncapped 12.6A Multi-Split Current & Capacity Envelope (Mitsubishi MXY-3H28VG)
Singapore HDB 8.5A vs Uncapped 12.6A Multi-Split Current & Capacity Envelope (Mitsubishi MXY-3H28VG)① HDB 8.5A isolator current ceiling (8.50 A / 1.92 kW max input); ② Uncapped private/new-HDB envelope (12.60 A / 2.84 kW max input); ③ 3-Room (10+10+20) rated 6.50 kW (22,178 BTU/h) vs peak 7.20 kW / 8.90 kW output.