Mitsubishi Electric · Homeowner Summary + Technical Datasheet
Mitsubishi Electric Starmex R32 8.5A HDB System 3 with 18K Living Room Wall Unit (MXY-3H28VG 8.5A / 2× MSXY-FP10VG + 1× MSXY-FP18VG)
Cooling Capacity
21,154 BTU/h
6.2 kW nominal
Efficiency
5.44 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$3,850
Power: ~S$674/yr
Complete Technical Encyclopedia Datasheet
| Outdoor / Indoor Unit SKU | MXY-3H28VG (8.5A) / 2× MSXY-FP10VG (2× 2.8 kW Bedroom Wall) + 1× MSXY-FP18VG (5.0 kW Living Room Wall) |
|---|---|
| System Architecture & Compressor | Multi-Split System 3 — 8.5A HDB Current-Limited (9K + 9K + 18K Combination) · Twin-Rotary DC Inverter (MXY-3H28VG 8.5A HDB Current-Limited Condenser) |
| Rated Capacity & Inverter Modulation | 21,154 BTU/h (6.2 kW) · Modulation: 8,189–24,566 BTU/h (6.20 kW nominal / 2.40–7.20 kW min-max under 8.50 A HDB current limit) |
| Efficiency Index & Tick Standing | WCOP 5.44 / COP 5.44 in 10+10+18 8.5A HDB mode (1.14 kW nominal power input, 0.48–1.92 kW min-max; 5.06 A nominal running current, 2.13–8.50 A max cap) · 5 |
| Indoor & Outdoor Sound Pressure | Indoor: 19–45 dBA (MSXY-FP10VG bedrooms) / 28–49 dBA (MSXY-FP18VG living room) · Outdoor Condenser: 49 dBA |
| Refrigerant, Copper Pipe Size & Max Span | R32 · 3× Ø6.35 mm (1/4") liquid / 2× Ø9.52 mm (3/8") gas (FP10VG) + 1× Ø12.70 mm (1/2") gas (FP18VG via port adaptor) · 60 |
| Troubleshooting & Age Lookup | Mitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker |
| Verified Manufacturer Datasheet | Mitsubishi Electric Starmex R32 Multi-Split Catalogue (MXY-3H28VG 8.5A HDB 10+10+18 Combination Table, Pages 17, 20 & 29) ↗ |
Engineering Reference