Mitsubishi Electric Starmex R32 System 3 9K + 9K + 18K Full-Capacity Multi-Split (MXY-3H28VG + 2× MSXY-FP10VG + MSXY-FP20VG)

In Plain English: Suited for Whole Flat / 2–4 Rooms, running at 19 dBA (Whisper-quiet bedroom) on low fan speed. Expect an estimated electricity bill of ~S$696/year (~S$58/month) at 8 hrs/day. Complete factory-tested System 3 R32 combination pairing outdoor condenser MXY-3H28VG (840 × 330 × 710 mm, 55 kg, 1.65 kg R32 factory pre-charge, 49 dBA) with two MSXY-FP10VG bedroom FCUs (2.8 kW class each, 19–42 dBA, 0.19 A each) and one wide-chassis MSXY-FP20VG living room FCU (6.0 kW class, 923 × 250 × 305 mm, 29–49 dBA, 0.38 A). Per Page 27 & 29 of the Mitsubishi Electric Singapore R32 Catalogue, the 10+10+20 pairing unlocks the full 6.50 kW (22,178 BTU/h) nominal cooling ceiling of MXY-3H28VG (allocated as 1.57 kW + 1.57 kW + 3.36 kW under simultaneous full load, 2.40–8.90 kW min–max) at 1.33 kW nominal power input (0.48–2.84 kW) and 5.90 A running current (2.13–12.60 A). In 8.5A HDB jumper mode (Page 29), max cooling is capped at 7.20 kW with 1.92 kW / 8.50 A max input. Combined indoor current is 0.76 A (well within the <= 3.0 A limit).
Cooling Capacity
22,178 BTU/h
6.5 kW nominal
Efficiency
5.52 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$4,150
Power: ~S$696/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUMXY-3H28VG / 2× MSXY-FP10VG + 1× MSXY-FP20VG
System Architecture & CompressorMulti-Split System 3 (Wall-Mounted 2 Bedrooms + Large Living Room) · Twin Rotary DC Inverter Compressor with PAM Control
Rated Capacity & Inverter Modulation22,178 BTU/h (6.5 kW) · Modulation: 8,189 – 30,367 BTU/h (2.40 – 8.90 kW Standard · 2.40 – 7.20 kW in 8.5A HDB Mode)
Efficiency Index & Tick StandingWCOP 5.52 W/W (NEA 5-Tick · 4.89 W/W Full-Load COP at 6.50 kW / 1.33 kW Input) · 5
Indoor & Outdoor Sound PressureIndoor: 19–42 dBA (2× MSXY-FP10VG Bedrooms) / 29–49 dBA (MSXY-FP20VG Living) · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · 3× Ø6.35 mm Liquid / 3× Ø9.52 mm Gas (Outdoor Ports; Ø12.70 mm Gas Flare on MSXY-FP20VG) · 60
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Singapore — Starmex R32 Inverter Multi-Split Catalogue (MXY-3H28VG 10+10+20 Combination Table, Pages 20, 27 & 29) ↗
How a System 3 Aircon Connects (3 Indoor Units to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 3 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)CONNECTED #2Room 2 · Common Bedroom 2 (9K BTU)CONNECTED #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$3,177S$6,8674-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$3,955S$7,145Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$5,491S$8,241
Engineering Reference

Technical Schematic

Mitsubishi Electric MXY-3H28VG System 3 10+10+20 Full-Capacity (6.50 kW) vs 10+10+10 (6.20 kW) Allocation Schematic
Mitsubishi Electric MXY-3H28VG System 3 10+10+20 Full-Capacity (6.50 kW) vs 10+10+10 (6.20 kW) Allocation SchematicNordic Thermal engineering comparison of Mitsubishi Electric MXY-3H28VG System 3 capacity allocation: 10+10+10 (2.07 + 2.07 + 2.07 = 6.20 kW at 1.16 kW / 5.15 A) vs 10+10+20 (1.57 + 1.57 + 3.36 = 6.50 kW full rated ceiling at 1.33 kW / 5.90 A, or 7.20 kW / 1.92 kW / 8.50 A max in HDB 8.5A jumper mode) per Pages 20, 27 & 29 of the Starmex R32 Catalogue.