Mitsubishi Electric · Homeowner Summary + Technical Datasheet

Mitsubishi Electric Starmex R32 System 3 9K + 9K + 12K Three-Bedroom Multi-Split (MXY-3H28VG + 2× MSXY-FP10VG + MSXY-FP13VG)

In Plain English: Suited for Whole Flat / 2–4 Rooms, running at 19 dBA (Whisper-quiet bedroom) on low fan speed. Expect an estimated electricity bill of ~S$664/year (~S$55/month) at 8 hrs/day. Complete factory-tested System 3 bedroom package for 4-room HDB flats and 3-bedroom condos: pairs the MXY-3H28VG R32 outdoor condenser (840 × 330 × 710 mm, 55 kg, 38.7 m³/min outdoor airflow, 49 dBA, 1.65 kg R32 factory pre-charge) with two MSXY-FP10VG 9,000 BTU class common-bedroom units (2.8 kW solo each, 19–45 dBA, 0.028 kW / 0.27 A each) and one MSXY-FP13VG 12,000 BTU class master-bedroom unit (3.5 kW solo, 19–47 dBA, 0.036 kW / 0.33 A). All three indoor units share the compact 799 × 232 × 290 mm (9 kg) chassis and connect directly to the outdoor condenser's native 3× Ø6.35 mm liquid and 3× Ø9.52 mm (3/8 in) gas ports without flare reducers. Per Page 27 of the Mitsubishi Electric Starmex R32 Catalogue, simultaneous 3-room operation delivers 1.91 + 1.91 + 2.38 = 6.20 kW (21,154 BTU/h) nominal cooling (2.40–8.80 kW min–max) at 1.15 kW nominal power input (0.48–2.86 kW) and 5.10 A running current (2.13–12.67 A; COP 5.39; NEA 5-Tick WCOP 5.52). Under HDB 8.5A current-limit mode (Page 29), cooling is 2.40–7.10 kW at 1.16 kW / 5.15 A nominal and 1.92 kW / 8.50 A max. Combined indoor running current is 0.87 A (<= 3.0 A limit).
Cooling Capacity
21,154 BTU/h
6.2 kW nominal
Efficiency
5.52 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$3,820
Power: ~S$664/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUMXY-3H28VG / 2× MSXY-FP10VG (2× 2.8 kW Common Bedrooms) + 1× MSXY-FP13VG (3.5 kW Master Bedroom)
System Architecture & CompressorMulti-Split System 3 (Wall-Mounted 2× 9K Common + 1× 12K Master Bedroom Trio) · Twin Rotary DC Inverter Compressor with PAM Control
Rated Capacity & Inverter Modulation21,154 BTU/h (6.2 kW) · Modulation: 8,189 – 30,026 BTU/h (6.20 kW Nominal: 1.91 + 1.91 + 2.38 kW · 2.40–8.80 kW Standard · 2.40–7.10 kW in 8.5A HDB Mode)
Efficiency Index & Tick StandingWCOP 5.52 W/W (NEA 5-Tick · 5.39 W/W Nominal COP at 6.20 kW / 1.15 kW Input) · 5
Indoor & Outdoor Sound PressureIndoor: 19–45 dBA (2× MSXY-FP10VG Common Bedrooms) / 19–47 dBA (MSXY-FP13VG Master Bedroom) · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · 3× Ø6.35 mm (1/4 in) Liquid / 3× Ø9.52 mm (3/8 in) Native Gas Flared (Zero Flare Reducers Required) · 60
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Singapore — Starmex R32 Inverter Multi-Split Catalogue (MXY-3H28VG 10+10+13 Combination Table, Pages 20, 27 & 29) ↗
How a System 3 Aircon Connects (3 Indoor Units to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 3 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)CONNECTED #2Room 2 · Common Bedroom 2 (9K BTU)CONNECTED #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$3,030S$6,7204-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$3,772S$6,962Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$5,238S$7,988
Engineering Reference

Technical Schematic

Mitsubishi Electric Starmex System 3 (MXY-3H28VG) Bedroom Progression: 10+10+10 (3× 9K) vs 10+10+13 (2× 9K + 12K) vs 10+13+13 (9K + 2× 12K)
Mitsubishi Electric Starmex System 3 (MXY-3H28VG) Bedroom Progression: 10+10+10 (3× 9K) vs 10+10+13 (2× 9K + 12K) vs 10+13+13 (9K + 2× 12K)① 10+10+10 (Page 27): 2.07 + 2.07 + 2.07 = 6.20 kW at 1.16 kW / 5.15 A; ② 10+10+13 (Page 27): 1.91 + 1.91 + 2.38 = 6.20 kW at 1.15 kW / 5.10 A (+15% simultaneous master-bedroom cooling & 3.50 kW solo); ③ 10+13+13 (Page 27): 1.77 + 2.21 + 2.21 = 6.20 kW at 1.13 kW / 5.01 A.