Mitsubishi Electric Starmex R32 Hybrid 5.0 kW Middle-Static Concealed Ducted + Wall System 2 (MXY-2H20VF / 1× PEY-M50JAL Ducted + 1× MSXY-FP10VG Wall)

In Plain English: Suited for Whole Flat / 2–4 Rooms, running at 19 dBA (Whisper-quiet bedroom) on low fan speed. Expect an estimated electricity bill of ~S$482/year (~S$40/month) at 8 hrs/day. Official Mitsubishi Electric Starmex R32 Catalogue (Pages 20, 22 & 26) Hybrid System 2 pairing the compact MXY-2H20VF outdoor condenser (800×285×550 mm, 37 kg, 32.9 m³/min outdoor airflow, 49 dBA, 1.20 kg R32 factory pre-charge, 30 m max total pipe length / 20 m single FCU) with one PEY-M50JAL ceiling-concealed ducted unit (900×732×250 mm, 27.0 kg, 35–50–70–100–125 Pa selectable static pressure, 12.0–14.5–17.0 m³/min airflow, 0.11 kW input, 1.39 A running current) and one MSXY-FP10VG bedroom wall unit (0.27 A running current). Total indoor unit running current is 1.39 + 0.27 = 1.66 A (well within the 3.0 A MXY-H indoor current ceiling). Simultaneous 2-room operation delivers 1.47 + 2.63 = 4.10 kW nominal cooling (1.60–6.40 kW min-max) at 0.90 kW nominal power input and 4.76 A nominal running current.
Cooling Capacity
15,354 BTU/h
4.5 kW nominal
Efficiency
5.52 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$3,780
Power: ~S$482/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUMXY-2H20VF / 1× PEY-M50JAL (5.0 kW Middle-Static Ducted) + 1× MSXY-FP10VG (2.8 kW Wall)
System Architecture & CompressorMulti-Split Hybrid System 2 (Middle-Static Concealed Ducted + Wall-Mounted) · Twin-Rotary DC Inverter (MXY-2H20VF 5-Tick Outdoor Condenser)
Rated Capacity & Inverter Modulation15,354 BTU/h (4.5 kW) · Modulation: 4,436–22,178 BTU/h (4.5 kW rated / 1.3–6.5 kW min-max outdoor capacity)
Efficiency Index & Tick StandingWCOP 5.52 / COP 4.95 (0.91 kW rated outdoor power input at 230V, 4.88 A outdoor running current) · 5
Indoor & Outdoor Sound PressureIndoor: 19–42 dBA (MSXY-FP10VG Bedroom Wall) / 30–35–39 dBA at 50 Pa ESP & 12.0–14.5–17.0 m³/min airflow (PEY-M50JAL Middle-Static Ceiling Ducted) · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · Ø6.35 mm liquid / Ø12.70 mm gas (PEY-M50JAL ducted port) & Ø6.35 mm / Ø9.52 mm (MSXY-FP10VG port) · 30
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Starmex R32 Multi-Split & Hybrid System Catalogue (MXY-2H20VF & PEY-M50JAL Specifications, Pages 3, 20 & 22) ↗
How a System 2 Aircon Connects (2 Indoor Units to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 2 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)CONNECTED #2Room 2 · Common Bedroom 2 (9K BTU)UNUSED PORT #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$2,199S$5,8894-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$2,738S$5,928Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$3,802S$6,552
Engineering Reference

Technical Schematic

Mitsubishi Electric Starmex MXY-2H20VF + PEY-M50JAL + MSXY-FP10VG Middle-Static Hybrid System 2 Schematic
Mitsubishi Electric Starmex MXY-2H20VF + PEY-M50JAL + MSXY-FP10VG Middle-Static Hybrid System 2 SchematicEngineering layout of the Mitsubishi Electric MXY-2H20VF 5-Tick R32 condenser (4.5 kW rated / 1.3–6.5 kW range) driving 1× PEY-M50JAL middle-static ceiling-concealed ducted unit (5.0 kW, 35–125 Pa, 1.39 A) and 1× MSXY-FP10VG wall unit (2.8 kW, 0.27 A) with 1.66 A total indoor draw (limit <= 3.0 A).