Mitsubishi Electric · Homeowner Summary + Technical Datasheet
Mitsubishi Electric Starmex R32 System 2 with 12K Master Bedroom + 20K Large Living Room Wall Units (MXY-2H20VF / 1× MSXY-FP13VG + 1× MSXY-FP20VG)
Cooling Capacity
15,354 BTU/h
4.5 kW nominal
Efficiency
5.52 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$3,180
Power: ~S$482/yr
Complete Technical Encyclopedia Datasheet
| Outdoor / Indoor Unit SKU | MXY-2H20VF / 1× MSXY-FP13VG (3.5 kW Master Bedroom Wall) + 1× MSXY-FP20VG (4.5 kW Solo / 6.0 kW Class Large Living Room Wall) |
|---|---|
| System Architecture & Compressor | Multi-Split System 2 (12K Master Bedroom + 20K Large Living Room High-Capacity Wall Combination) · Twin-Rotary DC Inverter (MXY-2H20VF 2-Port Condenser) |
| Rated Capacity & Inverter Modulation | 15,354 BTU/h (4.5 kW) · Modulation: 5,800–22,178 BTU/h (4.50 kW full nominal ceiling / 1.70–6.50 kW min–max in 2-room 13+20 mode; 1.70–5.80 kW in 8.5A HDB mode; 3.50 kW solo master bedroom / 4.50 kW solo living room) |
| Efficiency Index & Tick Standing | WCOP 5.52 / COP 4.95 in 2-room 13+20 mode (0.91 kW nominal power input, 0.34–2.26 kW min–max; 4.88 A nominal running current, 1.83–12.13 A min–max; 0.34–1.58 kW / 1.83–8.50 A in 8.5A HDB mode) · 5 |
| Indoor & Outdoor Sound Pressure | Indoor: 19–47 dBA (MSXY-FP13VG Master Bedroom: 4.1–14.1 m³/min) / 30–50 dBA (MSXY-FP20VG Large Living Room: 9.3–20.0 m³/min) · Outdoor Condenser: 49 dBA |
| Refrigerant, Copper Pipe Size & Max Span | R32 · 2× Ø6.35 mm (1/4") liquid / 2× Ø9.52 mm (3/8") outdoor gas ports (uses optional PAC-SG76RJ-E Ø9.52→Ø12.7 mm gas joint for MSXY-FP20VG per Note 3) · 30 |
| Troubleshooting & Age Lookup | Mitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker |
| Verified Manufacturer Datasheet | Mitsubishi Electric Starmex R32 Multi-Split Catalogue (MXY-2H20VF 13+20 Combination Capacity Tables, Pages 18, 20, 28 & 29) ↗ |
Engineering Reference