In Plain English: Suited for Whole Flat / 2–4 Rooms, running at 19 dBA (Whisper-quiet bedroom) on low fan speed. Expect an estimated electricity bill of ~S$450/year (~S$38/month) at 8 hrs/day. Complete paired R32 System 2 configuration published on Pages 18, 20, and 28 of the official Mitsubishi Electric Starmex R32 Singapore catalogue, combining the MXY-2H20VF outdoor condenser (800 × 285 × 550 mm, 37 kg net weight, 49 dBA sound pressure, 32.9 m³/min outdoor airflow, 1.20 kg R32 factory pre-charge, 15 A breaker) with one MSXY-FP13VG master bedroom wall unit (799 × 232 × 290 mm, 9 kg, 19–22–29–37–47 dBA across 4.1–5.1–6.3–9.1–14.1 m³/min airflow, 0.032 kW indoor power, 0.33 A running current, Ø6.35 / Ø9.52 mm piping) and one MSXY-FP18VG living room wall unit (799 × 232 × 290 mm, 9 kg, 28–33–38–44–49 dBA across 6.2–7.7–9.5–12.1–14.8 m³/min airflow, 0.043 kW indoor power, 0.38 A running current, Ø6.35 / Ø12.7 mm piping connected via optional PAC-SG76RJ-E Ø9.52→Ø12.7 mm port adapter; combined indoor current 0.71 A <= 3.0 A MXY-H limit). In simultaneous 2-room 13+18 operation (Page 28), delivers 4.20 kW (14,330 BTU/h) nominal cooling (proportional allocation: 1.73 kW to MSXY-FP13VG + 2.47 kW to MSXY-FP18VG; 1.60–6.50 kW min–max envelope) at 0.84 kW nominal power input (0.34–2.26 kW min–max; 0.34–1.58 kW in 8.5A HDB current-limit mode) and 4.51 A nominal running current (1.83–12.13 A min–max; 1.83–8.50 A in 8.5A HDB mode). When operating a single room solo, MSXY-FP13VG delivers its full 3.50 kW (1.40–4.00 kW) rated output at 0.79 kW / 4.24 A, while MSXY-FP18VG delivers 4.50 kW (1.50–5.00 kW) at 1.20 kW / 6.44 A.
Cooling Capacity
14,330 BTU/h
4.2 kW nominal
Efficiency
5.52 WCOP
5
Sleep Quietness
19 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$2,890
Power: ~S$450/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUMXY-2H20VF / MSXY-FP13VG × 1 + MSXY-FP18VG × 1
System Architecture & CompressorSystem 2 Multi-Split Inverter (12K Master Bedroom + 18K Living Room High-Capacity Wall-Mounted Pairing) · Twin Rotary DC Inverter (PAM Control)
Rated Capacity & Inverter Modulation14,330 BTU/h (4.2 kW) · Modulation: 5,459 – 22,178 (2-room simultaneous) / 11,942 solo FP13VG / 15,354 solo FP18VG (5,118 – 17,060)
Efficiency Index & Tick StandingWCOP 5.52 (NEA 5 Ticks · 0.84 kW nominal power input at 4.20 kW simultaneous 2-room cooling) · 5
Indoor & Outdoor Sound PressureIndoor: 19 – 47 (MSXY-FP13VG) / 28 – 49 (MSXY-FP18VG) · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · 6.35 × 2 / 9.52 × 2 (requires optional PAC-SG76RJ-E Ø9.52→Ø12.7 mm joint for MSXY-FP18VG gas line) · 30
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Starmex R32 Inverter Multi Split Air-Conditioners Official Singapore Catalogue (Pages 18, 20 & 28) ↗
How a System 2 Aircon Connects (2 Indoor Units to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 2 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)CONNECTED #2Room 2 · Common Bedroom 2 (9K BTU)UNUSED PORT #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$1,550 + 5-Yr Electricity S$2,053S$3,6034-Tick Standard Inverter (WCOP 4.86)Upfront S$1,220 + 5-Yr Electricity S$2,555S$3,775Older Aging Aircon (COP 3.50)Upfront S$980 + 5-Yr Electricity S$3,548S$4,528
Engineering Reference

Technical Schematic

Mitsubishi Electric Starmex MXY-2H20VF R32 System 2 High-Capacity Pairing Matrix: 13+18 vs 10+18 vs 13+13 (Page 28)
Mitsubishi Electric Starmex MXY-2H20VF R32 System 2 High-Capacity Pairing Matrix: 13+18 vs 10+18 vs 13+13 (Page 28)Factory capacity allocation, power input, running current, and port-adapter engineering comparison across 10+18 (4.10 kW), 13+13 (4.10 kW), and 13+18 (4.20 kW) on the MXY-2H20VF R32 System 2 outdoor unit (Mitsubishi Electric Singapore Catalogue Pages 18, 20 & 28).