Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Mitsubishi Electric · Homeowner Summary + Technical Datasheet

Starmex FP-Series R32 Multi-Split Wall-Mounted 24K Flagship Indoor Unit (MSXY-FP24VG)

Indoor FCU Only (Requires Multi-Split Condenser)

In Plain English: Suited for Living & Dining Room (420–650 sq ft), running at 30 dBA (Soft living-room breeze) on low fan speed. Its electricity bill depends on paired multi-split condenser, because this is an indoor unit only. Indoor-only 7.1 kW (24,225 BTU/h class) flagship Starmex R32 wall-mounted multi-split FCU (923 × 250 × 305 mm, 13 kg net weight) drawing 0.059 kW power input and 0.52 A running current (counted toward the <= 3.0 A maximum combined indoor running current budget on MXY-H multi-split condensers). Delivers 5-step airflow of 9.3–11.1–13.7–16.1–20.0 m³/min at 30–35–41–45–50 dBA sound pressure with Dual Barrier Coating, Electrostatic Anti-Allergy Enzyme Filter (optional MAC-EMF515FT-E Microparticle Catching Filter), and Ø6.35 mm liquid / Ø12.70 mm gas flared piping. Compatible with MXY-3H28VG, MXY-4H33VG, MXY-4H38VG, and MXY-5H48VG condensers (explicitly excluded from MXY-2H20VF per Pages 3 and 18).
Cooling Capacity
24,225 BTU/h
7.1 kW nominal
Efficiency
5.75 WCOP
5
Sleep Quietness
30 dBA
Outdoor: 49 dBA
Per-Zone FCU Allocation (Excludes Outdoor Condenser)
~S$1,920
Power: Depends on Paired Multi-Split Condenser

Complete Technical Encyclopedia Datasheet

Indoor Unit SKUMSXY-FP24VG
Compatible Multi-Split CondensersMXY-3H28VG / MXY-4H33VG / MXY-4H38VG / MXY-5H48VG (Compatible R32 Multi-Split Condensers; Not Applicable to MXY-2H20VF)
System Architecture & CompressorMulti-Split Wall-Mounted FCU (24K Flagship Large Living / Dining Unit) · Mitsubishi Electric Twin-Rotary DC Inverter (MXY-3H/4H/5H Series)
Rated Capacity & Inverter Modulation24,225 BTU/h (7.1 kW) · Modulation: 24,225 BTU/h Nominal Class (7.1 kW Multi-Split Wall FCU · 0.059 kW / 0.52 A Indoor Input)
Efficiency Index & Tick StandingNEA 5-Tick Multi-Split (0.059 kW Indoor Fan Input / 0.52 A Running Current) · 5
Indoor & Outdoor Sound PressureIndoor: 30 / 35 / 41 / 45 / 50 dBA (Lo-Mi1-Mi2-Hi-SHi) · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · Ø6.35 mm (1/4 in) Liquid / Ø12.70 mm (1/2 in) Gas Flared · 25
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Singapore — Starmex R32 Inverter Multi-Split Catalogue (MSXY-FP24VG Indoor Unit Specifications, Pages 3, 18 & 20) ↗
How a System 1 Aircon Connects (1 Indoor Unit to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 1 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)UNUSED PORT #2Room 2 · Common Bedroom 2 (9K BTU)UNUSED PORT #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe