Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Mitsubishi Electric · Homeowner Summary + Technical Datasheet

Mitsubishi Electric Mr Slim PLY-Series R32 Single-Split 21K 4-Way Ceiling Cassette (PLY-M60EA / SUY-M60VA)

In Plain English: Suited for Living & Dining Room (420–650 sq ft), running at 28 dBA (Soft living-room breeze) on low fan speed. Expect an estimated electricity bill of ~S$810/year (~S$68/month) at 8 hrs/day. Official Mitsubishi Electric Singapore R32 Inverter 4-way ceiling cassette single-split (PLY-M60EA indoor / SUY-M60VA outdoor, PLP-6EAE grille; 6.0 kW / 20,472 BTU/h rated, 6.5 kW / 22,178 BTU/h max cooling; 1.37 kW rated power input; 6.30 A running current). Delivers 16-18-20-23 m3/min 4-step airflow at 28-31-34-37 dBA indoor sound pressure (54 dBA outdoor) across a slim 840x840x258 mm (21 kg + 5 kg panel) cassette body and 800x285x714 mm (35 kg) outdoor unit with Multiflow Condenser (MFC), 0.85 kg R32 factory pre-charge, and 30 m max pipe length (15 m max height difference) on 9.52 mm (3/8") liquid and 15.88 mm (5/8") gas flared piping.
Cooling Capacity
20,472 BTU/h
6.0 kW nominal
Efficiency
4.38 WCOP
5
Sleep Quietness
28 dBA
Outdoor: 48 dBA
Est. Upfront + Install
~S$2,880
Power: ~S$810/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUSUY-M60VA / PLY-M60EA
System Architecture & CompressorSingle-Split 4-Way Ceiling Cassette (21K Commercial / Landed Living Unit) · DC Inverter Twin-Rotary Compressor with Multiflow Condenser (MFC)
Rated Capacity & Inverter Modulation20,472 BTU/h (6.0 kW) · Modulation: 20,472 BTU/h Rated / 22,178 BTU/h Max (6.0 kW Rated, 6.5 kW Max)
Efficiency Index & Tick StandingNEA 5-Tick Single-Split Ceiling Cassette (1.37 kW Input / 6.30 A Running Current) · 5
Indoor & Outdoor Sound PressureIndoor: 28 - 31 - 34 - 37 dBA (Low - Mid2 - Mid1 - High) · Outdoor Condenser: 48 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · Ø9.52 mm Liquid / Ø15.88 mm Gas · 20
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Singapore — Starmex R32 Inverter Catalogue (PLY-M60EA / SUY-M60VA 4-Way Ceiling Cassette Specifications, Page 24) ↗
How a System 1 Aircon Connects (1 Indoor Unit to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 1 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)UNUSED PORT #2Room 2 · Common Bedroom 2 (9K BTU)UNUSED PORT #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$2,933S$6,6234-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$3,651S$6,841Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$5,069S$7,819