Mitsubishi Electric Mr. Slim PEY-M80JAL2 / SUY-M80VA (27.3K BTU Concealed Ceiling Ducted)

In Plain English: Suited for Living & Dining Room (420–650 sq ft), running at 29.0 dBA (Soft living-room breeze) on low fan speed. Expect an estimated electricity bill of ~S$1,272/year (~S$106/month) at 8 hrs/day. Single-phase 230V/50Hz R32 Mr. Slim ceiling-concealed ducted commercial pair (PEY-M80JAL2 indoor 1100×732×250 mm, 30 kg; SUY-M80VA outdoor 840×330×880 mm, 43 kg, 0.96 kg R32 pre-charge). Delivers 8.0 kW (27,296 BTU/h) rated cooling (8.9 kW / 30,367 BTU/h max) at 2.15 kW rated power input (9.7 A running current), 3-step airflow (17.5–21.0–25.0 m³/min at 29–33–37 dBA), and 30 m max piping length (15 m max height difference).
Cooling Capacity
27,300 BTU/h
8.0 kW nominal
Efficiency
3.72 WCOP
Sleep Quietness
29.0 dBA
Outdoor: 54.0 dBA
Est. Upfront + Install
~S$4,120
Power: ~S$1,272/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUSUY-M80VA / PEY-M80JAL2
System Architecture & CompressorCommercial Concealed Ceiling Ducted Split (1-to-1, 1-Phase 230V 50Hz) · DC Inverter Twin Rotary Compressor with PAM Control & Joint Wrap DC Motor
Rated Capacity & Inverter Modulation27,300 BTU/h (8.0 kW) · Modulation: 27,300 – 30,370
Efficiency Index & Tick StandingCOP 3.72 W/W (2.15 kW Rated Input at 8.0 kW Rated Load; 8.9 kW Max) ·
Indoor & Outdoor Sound PressureIndoor: 29 - 33 - 37 dBA (3-step 17.5 - 21.0 - 25.0 m³/min airflow) · Outdoor Condenser: 54.0 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · 9.52 mm (3/8") liquid / 15.88 mm (5/8") gas (flared) · 30
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Starmex R32 & Mr. Slim Commercial Catalogue SG (Page 25) ↗
How a System 1 Aircon Connects (1 Indoor Unit to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 1 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)UNUSED PORT #2Room 2 · Common Bedroom 2 (9K BTU)UNUSED PORT #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$3,911S$7,6014-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$4,868S$8,058Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$6,760S$9,510