Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Mitsubishi Electric · Homeowner Summary + Technical Datasheet

Mitsubishi Electric Mr. Slim R32 Ceiling-Concealed Ducted 42.7K (PEY-M125JAL2 / PUY-M125VKA)

In Plain English: Suited for Living & Dining Room (420–650 sq ft), running at 36.0 dBA (Soft living-room breeze) on low fan speed. Expect an estimated electricity bill of ~S$2,392/year (~S$199/month) at 8 hrs/day. Single-phase 230V/50Hz R32 Mr. Slim ceiling-concealed ducted commercial pair (PEY-M125JAL2 indoor 1400×732×250 mm, 39 kg; PUY-M125VKA outdoor 1050×330×981 mm, 63 kg, 1.20 kg R32 pre-charge). Delivers 12.5 kW (42,650 BTU/h) rated cooling (14.0 kW / 47,768 BTU/h max) at 4.05 kW rated power input (18.2 A running current), 3-step airflow (29.5–35.5–42.0 m³/min at 36–40–44 dBA), and 50 m max piping length (30 m max height difference).
Cooling Capacity
42,700 BTU/h
12.5 kW nominal
Efficiency
3.09 WCOP
32
Sleep Quietness
36.0 dBA
Outdoor: 55.0 dBA
Est. Upfront + Install
~S$5,150
Power: ~S$2,392/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKUPUY-M125VKA / PEY-M125JAL2
System Architecture & CompressorCommercial Single-Split Ceiling-Concealed Ducted (1-Phase 230V 50Hz) · DC Inverter Twin Rotary Compressor (Multiflow Condenser)
Rated Capacity & Inverter Modulation42,700 BTU/h (12.5 kW) · Modulation: 18,800 – 47,800 BTU/h (12.5 kW Rated / 14.0 kW Max)
Efficiency Index & Tick StandingCOP 3.09 W/W (1-Phase Commercial R32) · 32
Indoor & Outdoor Sound PressureIndoor: 36 - 40 - 44 dBA (3-step 29.5 - 35.5 - 42.0 m³/min airflow) · Outdoor Condenser: 55.0 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · 9.52 mm (3/8") liquid / 15.88 mm (5/8") gas (flared) · 50
Troubleshooting & Age LookupMitsubishi Electric Error Codes · Mitsubishi Electric Serial Age Checker
Verified Manufacturer DatasheetMitsubishi Electric Starmex R32 & Mr. Slim Commercial Catalogue SG (Page 25) ↗
How a System 1 Aircon Connects (1 Indoor Unit to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 1 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)UNUSED PORT #2Room 2 · Common Bedroom 2 (9K BTU)UNUSED PORT #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$6,117S$9,8074-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$7,614S$10,804Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$10,573S$13,323