Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Hitachi Cooling & Heating · Homeowner Summary + Technical Datasheet

Hitachi airHome Ducted R32 Concealed Ceiling 24K (RAD-DJ70QHAE / RAC-DJ70QHAE)

In Plain English: Suited for Living & Dining Room (420–650 sq ft), running at 29 dBA (Soft living-room breeze) on low fan speed. Expect an estimated electricity bill of ~S$930/year (~S$78/month) at 8 hrs/day. Flagship 23,880 BTU/h (7.00 kW rated, up to 8.00 kW / 27,300 BTU/h peak) concealed ceiling ducted FCU delivering 50 / 100 / 150 Pa selectable static pressure, 350–1,140 m³/h airflow, and 29–39 dBA quiet operation from a 270 x 900 x 720 mm chassis using Ø15.88 mm (5/8") gas piping.
Cooling Capacity
23,880 BTU/h
7.0 kW nominal
Efficiency
4.45 WCOP
24
Sleep Quietness
29 dBA
Outdoor: 53 dBA
Est. Upfront + Install
~S$3,250
Power: ~S$930/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKURAC-DJ70QHAE / RAD-DJ70QHAE
System Architecture & CompressorConcealed Ceiling Ducted (24K Open-Plan Living/Penthouse Medium-Static FCU) · Hitachi High-Output Vector DC Rotary Inverter (R32)
Rated Capacity & Inverter Modulation23,880 BTU/h (7.0 kW) · Modulation: 5,120 – 27,300 BTU/h (1.50 – 8.00 kW)
Efficiency Index & Tick StandingSEER 6.80 (A++) / 50–150 Pa Selectable Static Pressure · 24
Indoor & Outdoor Sound PressureIndoor: 29 / 32 / 35 / 37 / 39 dBA (SL / L / M / H / SH) · Outdoor Condenser: 53 dBA
Refrigerant, Copper Pipe Size & Max SpanR32 · Ø6.35 mm (1/4") Liquid / Ø15.88 mm (5/8") Gas · 30
Troubleshooting & Age LookupHitachi Cooling & Heating Error Codes · Hitachi Cooling & Heating Serial Age Checker
Verified Manufacturer DatasheetHitachi Cooling & Heating Official airHome Ducted RAD-DJ70QHAE Technical Datatable ↗
How a System 1 Aircon Connects (1 Indoor Unit to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 1 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)UNUSED PORT #2Room 2 · Common Bedroom 2 (9K BTU)UNUSED PORT #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$3,421S$7,1114-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$4,258S$7,448Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$5,913S$8,663