In Plain English: Suited for Living & Dining Room (420–650 sq ft), running at 35 dBA (Soft living-room breeze) on low fan speed. Expect an estimated electricity bill of ~S$2,708/year (~S$226/month) at 8 hrs/day. 3-phase 380–415V 50Hz commercial 125-class middle-static pressure concealed ceiling ducted system delivering full 12.5 kW (42,700 BTU/h) rated capacity with 11-stage remote-selectable external static pressure (50 Pa rated, 50–150 Pa range), 36/30.5/25 m³/min airflow, low-profile 245x1,400x800mm (47 kg) indoor chassis, 73 kg RZR125MYM outdoor unit with 45 dBA night quiet mode, and VP25 condensate drain connection.
Cooling Capacity
42,700 BTU/h
12.5 kW nominal
Efficiency
2.73 WCOP
Sleep Quietness
35 dBA
Outdoor: 52 dBA
Est. Upfront + Install
~S$5,620
Power: ~S$2,708/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKURZR125MYM / FBQ125EVE
System Architecture & CompressorCommercial Concealed Ceiling Ducted Split (1-to-1, 3-Phase 380–415V 50Hz) · Hermetically Sealed Swing Inverter Compressor (1.92 kW Motor Output, 3-Phase 380–415V)
Rated Capacity & Inverter Modulation42,700 BTU/h (12.5 kW) · Modulation: 19,500 – 47,800
Efficiency Index & Tick StandingCOP 2.73 W/W (4.58 kW Rated Input at 12.5 kW Full Load) ·
Indoor & Outdoor Sound PressureIndoor: 35 – 40 dBA · Outdoor Condenser: 52 dBA
Refrigerant, Copper Pipe Size & Max SpanR410A · 9.5mm (3/8") / 15.9mm (5/8") · 50
Troubleshooting & Age LookupDaikin Error Codes · Daikin Serial Age Checker
Verified Manufacturer DatasheetDaikin Singapore — SkyAir Commercial Duct Connection Middle Static Pressure (FBQ125EVE / RZR125MYM 3-Phase Technical Specifications) ↗
How a System 1 Aircon Connects (1 Indoor Unit to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 1 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)UNUSED PORT #2Room 2 · Common Bedroom 2 (9K BTU)UNUSED PORT #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$6,117S$9,8074-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$7,614S$10,804Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$10,573S$13,323