Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Daikin · Homeowner Summary + Technical Datasheet

Daikin SkyAir FAQ100CVEA / RZR100MYM (3-Phase 34.1K BTU High-Capacity Wall-Mounted)

In Plain English: Suited for Living & Dining Room (420–650 sq ft), running at 41 dBA (Soft living-room breeze) on low fan speed. Expect an estimated electricity bill of ~S$1,991/year (~S$166/month) at 8 hrs/day. 3-phase 380–415V 50Hz commercial 100-class wall-mounted split system for server rooms, comms closets, and retail spaces without false ceilings, delivering 10.0 kW (34,100 BTU/h) rated capacity, 26/23/19 m³/min airflow, 340x1,200x240mm Fresh White indoor unit (17 kg), lighter 73 kg RZR100MYM 3-phase outdoor unit (with 1.9 kg R410A charge vs 78 kg / 3.35 kg on 1-phase RZR100LVVM), and VP13 drain connection.
Cooling Capacity
34,100 BTU/h
10.0 kW nominal
Efficiency
2.97 WCOP
Sleep Quietness
41 dBA
Outdoor: 49 dBA
Est. Upfront + Install
~S$4,680
Power: ~S$1,991/yr

Complete Technical Encyclopedia Datasheet

Outdoor / Indoor Unit SKURZR100MYM / FAQ100CVEA
System Architecture & CompressorCommercial High-Capacity Wall-Mounted Split (1-to-1, 3-Phase 380–415V 50Hz) · Hermetically Sealed Swing Inverter Compressor (1.92 kW Motor Output, 3-Phase 380–415V)
Rated Capacity & Inverter Modulation34,100 BTU/h (10.0 kW) · Modulation: 17,100 – 38,200
Efficiency Index & Tick StandingCOP 2.97 W/W (3.37 kW Rated Input at 10.0 kW Full Load) ·
Indoor & Outdoor Sound PressureIndoor: 41 – 49 dBA · Outdoor Condenser: 49 dBA
Refrigerant, Copper Pipe Size & Max SpanR410A · 9.5mm (3/8") / 15.9mm (5/8") · 50
Troubleshooting & Age LookupDaikin Error Codes · Daikin Serial Age Checker
Verified Manufacturer DatasheetDaikin Singapore — SkyAir Commercial Wall Mounted Type (FAQ100CVEA / RZR100MYM 3-Phase Technical Specifications) ↗
How a System 1 Aircon Connects (1 Indoor Unit to 1 Outdoor Condenser)1 Outdoor Condenser (Ledge)4 ValvesSWG 21/22 Copper · R32Cooling 1 of 4 RoomsCONNECTED #1Room 1 · Master Bedroom (9K–12K BTU)UNUSED PORT #2Room 2 · Common Bedroom 2 (9K BTU)UNUSED PORT #3Room 3 · Study / Bedroom 3 (9K BTU)UNUSED PORT #4Room 4 · Living & Dining Zone (18K BTU)16mm Drain Pipe
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$4,885S$8,5754-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$6,081S$9,271Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$8,444S$11,194