Everyday Aircon Guide & Technical Specs Encyclopedia
100% Manual-Verified (12 Brands · 187 Models · 467 Fault Codes) · NEA & ENERGY STAR Grounded
Head-to-Head Comparison

Mitsubishi Starmex Hybrid Slim Ducted System 3: 5.0 kW SEZ-M50DAL vs 7.1 kW SEZ-M71DAL on MXY-3H28VG

Key Difference at a Glance: Compares the 5.0 kW SEZ-M50DAL slim ducted living-room FCU (990×700×200 mm, 22 kg, 10.0–12.5–15.0 m³/min airflow, 30–34–37 dBA, 0.63 A running current, Ø12.70 mm gas pipe) against the wider 7.1 kW SEZ-M71DAL slim ducted FCU (1190×700×200 mm, 25.5 kg, 12.0–16.0–20.0 m³/min airflow, 30–35–40 dBA, 0.84 A running current, Ø15.88 mm gas pipe) when paired with 2× MSXY-FP10VG bedroom wall units on the 5-Tick MXY-3H28VG condenser.
What MattersMitsubishi Electric Starmex R32 Hybrid 5.0 kW Slim 200mm Ducted + Wall System 3 (MXY-3H28VG / 1× SEZ-M50DAL Ducted + 2× MSXY-FP10VG Wall)Mitsubishi Electric Starmex R32 Hybrid 7.1 kW Slim Concealed Ducted + Wall System 3 (MXY-3H28VG / 1× SEZ-M71DAL Ducted + 2× MSXY-FP10VG Wall)
Est. Yearly Electricity Bill
8 hrs/day @ SP 31.16¢/kWh
~S$693/yr (~S$58/mo)~S$707/yr (~S$59/mo)
5-Year Total CostS$8,345 (Upfront ~S$4,880)S$8,515 (Upfront ~S$4,980)
Bedroom Quietness19 dBA (30 – 34 – 37 dBA (SEZ-M50DAL Ducted at 15 Pa) / 19 – 24 – 29 – 36 – 45 dBA (MSXY-FP10VG Wall))30.0 dBA (30 - 35 - 40 dBA (SEZ-M71DAL ducted at 15 Pa) / 19 - 45 dBA (MSXY-FP10VG wall))
Cooling Power22,178 BTU/h (6.5 kW)22,178 BTU/h (6.5 kW)
Efficiency RatingWCOP 5.55 W/W (NEA 5-Tick Multi-Split Class · 1.33 kW Rated Input / 5.93 A Outdoor Running Current) · 5WCOP 5.44 (NEA 5 Ticks, CSPF-class R32 PAM Inverter) · 5
Exact Outdoor / Indoor SKUMXY-3H28VG / 1× SEZ-M50DAL (5.0 kW Slim 200mm Ducted) + 2× MSXY-FP10VG (2.8 kW Wall)MXY-3H28VG / 1× SEZ-M71DAL (7.1 kW Slim Ducted) + 2× MSXY-FP10VG (2× 2.8 kW Wall)
Refrigerant & Pipe RunR32 · Outdoor Ports: 3× Ø9.52 mm Gas / 3× Ø6.35 mm Liquid (SEZ-M50DAL FCU uses Ø12.70 mm Gas / Ø6.35 mm Liquid with flare reducer at condenser port) · 60R32 · 9.52 mm liquid / 15.88 mm gas (Port A for SEZ-M71DAL) & 6.35 mm liquid / 9.52 mm gas (Ports B–C for MSXY-FP10VG) · 60
Official Spec SheetMitsubishi Electric Singapore — Official Starmex R32 Catalogue PDF (Pages 3, 20 & 23: MXY-3H28VG + SEZ-M50DAL + MSXY-FP10VG) ↗Mitsubishi Electric Starmex R32 & Mr. Slim Commercial Catalogue SG (Pages 3, 20 & 23) ↗
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$3,177S$6,8674-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$3,955S$7,145Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$5,491S$8,241
Engineering Reference

Technical Schematic

Mitsubishi Electric Starmex Hybrid Slim Ducted System 3 Matrix: SEZ-M50DAL (5.0 kW) vs SEZ-M71DAL (7.1 kW) on MXY-3H28VG
Mitsubishi Electric Starmex Hybrid Slim Ducted System 3 Matrix: SEZ-M50DAL (5.0 kW) vs SEZ-M71DAL (7.1 kW) on MXY-3H28VGEngineering comparison between the 5.0 kW SEZ-M50DAL (990 mm width, 10.0–15.0 m³/min, 0.63 A) and 7.1 kW SEZ-M71DAL (1190 mm width, 12.0–20.0 m³/min, 0.84 A) 200 mm-high concealed ducted units paired with 2× MSXY-FP10VG wall FCUs on the 5-Tick MXY-3H28VG condenser.