Daikin SkyAir Round Flow Cassette 17.1K (FCQ50LUV1) vs 20.5K (FCQ60LUV1)

Key Difference at a Glance: 5.0 kW (COP 4.85) vs 6.0 kW (COP 4.29) 1-to-1 Round Flow ceiling cassette sizing within identical 256×840×840 mm indoor and 595×845×300 mm RZR outdoor footprints
What MattersDaikin SkyAir Round Flow Ceiling Cassette 17.1K (FCQ50LUV1 / RZR50LWM)Daikin SkyAir Round Flow Ceiling Cassette 20.5K (FCQ60LUV1 / RZR60LWM)
Est. Yearly Electricity Bill
8 hrs/day @ SP 31.16¢/kWh
~S$610/yr (~S$51/mo)~S$827/yr (~S$69/mo)
5-Year Total CostS$6,500 (Upfront ~S$3,450)S$7,915 (Upfront ~S$3,780)
Bedroom Quietness28 dBA (28 – 35 dBA)28 dBA (28 – 35 dBA)
Cooling Power17,100 BTU/h (5.0 kW)20,500 BTU/h (6.0 kW)
Efficiency RatingCOP 4.85 W/W (1.03 kW Rated Input, 1-Phase 220–240V 50Hz) · 4COP 4.29 W/W (1.40 kW Rated Input, 1-Phase 220–240V 50Hz) · 4
Exact Outdoor / Indoor SKURZR50LWM / FCQ50LUV1RZR60LWM / FCQ60LUV1
Refrigerant & Pipe RunR410A · Ø9.5 mm Liquid / Ø15.9 mm Gas (VP25 Drain I.D. Ø25 mm × O.D. Ø32 mm) · 50R410A · Ø9.5 mm Liquid / Ø15.9 mm Gas (VP25 Drain I.D. Ø25 mm × O.D. Ø32 mm) · 50
Official Spec SheetDaikin Singapore Official SkyAir Ceiling Mounted Cassette Specifications ↗Daikin Singapore Official SkyAir Ceiling Mounted Cassette Specifications ↗
5-Year Total Cost: Upfront Unit + SP Group Electricity (8 hrs/day)5-Tick R32 Inverter (WCOP 6.05)Upfront S$3,690 + 5-Yr Electricity S$2,937S$6,6274-Tick Standard Inverter (WCOP 4.86)Upfront S$3,190 + 5-Yr Electricity S$3,656S$6,846Older Aging Aircon (COP 3.50)Upfront S$2,750 + 5-Yr Electricity S$5,076S$7,826